FSP HySpirit series User Manual
27
http://www.fsp-group.com.tw/en/product/PVInverter.html
14.
Operation
Operation and Display Panel
The operation and display panel, shown in the diagram below, is on the front panel of the
inverter. It includes three indicators, four function keys and a LCD display, indicating the
operating status and input/output power information.
LED Indicator
LED Indicator
Messages
Green
Solid On
Output is powered by utility in Line mode.
Flashing
Output is powered by battery or PV in battery mode.
Yellow
Solid On
Battery is fully charged.
Flashing
Battery is charging.
Red
Solid On
Fault occurs in the inverter.
Flashing
Warning condition occurs in the inverter.
Function Keys
Function Key
Description
/OFF
To exit setting mode
To go to previous selection or decrease value in setting mode
Enter setting mode
To go to next selection or increase value in setting mode
Enter setting mode
/ON
To confirm the selection in setting mode or turn on AC output
LCD Display Icons
LED indicators
Function keys
LCD display