FSP HySpirit series User Manual
12
http://www.fsp-group.com.tw/en/product/PVInverter.html
WARNING! Wrong connections may damage the unit permanently.
Step 4: Make sure the wires are securely connected. The reference tightening torque is 2.04 N.m.
WARNING! For safety and efficiency, it's very important to use appropriate cables for battery
connection. To reduce risk of injury, please use the proper cable size recommended as below.
Conductor cross-section (mm
2
)
38
AWG no.
2
9.
Load (AC Output) Connection
CAUTION: To prevent extra supply to the load via the inverter during any mode of operation, an
additional disconnection device should be placed on in the building wiring installation.
WARNING! For safety and efficiency, it's very important to use appropriate cable for AC
connection. To reduce risk of injury, please use the proper cable size recommended as below.
Model
5.5KW
Nominal Grid Voltage
230Vac
Conductor cross-section (mm
2
)
6
AWG no.
10
Step 1: Remove insulation sleeve 8 mm for three conductors. And shorten phase L and neutral
conductor N 3 mm. Refer to Diagram 3.
Step 2: Connect wires according to the polarities indicated on
terminal block. Be sure to connect PE
protective conductor (
) first. Refer to Diagram 4.
L
N
Diagram 3