FSP HySpirit series User Manual
17
http://www.fsp-group.com.tw/en/product/PVInverter.html
13.
Initial Setup
Before inverter starts to operate, it’s required to set up “Operation Mode” via software. Please
strictly follow the steps below to set up. For more details, please refer to software manual.
Step 1: After turning on the inverter and installing the software, please click “Open Monitor” to
enter main screen of this software.
Step 2: Log in the software first by entering the default password “administrator.”
Step 3: Select Device Control>>MyPower Management to set up inverter operation mode and
personalized interface. Refer to diagram below.
Mode
There are three operation modes: Grid-tie with backup, Grid-Tie and Off-Grid.
Grid-tie with backup: PV power can feed back to grid, provide power to the load and charge
battery. There are four options available in this mode: Grid-tie with backup I, II, III and IV. In
this mode, users can configure PV power supply priority, charging source priority and load
supply source priority. However, when Grid-tie with backup IV option is selected in PV energy
supply priority, the inverter is only operating between two working logics based on defined
peak time and off-peak time of electricity. Only peak time and off-peak time of electricity are
able to set up to optimize electricity usage.
Grid-Tie: PV power can only feed back to grid.
Off-Grid: PV power can only provide power to the load and charge battery but can’t feed
back to grid.
SECTION A:
Standard: It will list local grid standard. To make any modification, you’re requested to have
factory password. Please check local dealer only when this standard change is requested.
CAUTION: Wrong setting could cause damage to the unit or not working.