Automatic Filtering Fryers
4-30
CODE
ERROR MESSAGE
EXPLANATION
E01
M3000 ONLY
REMOVE DISCARD (Right)
A product cook is started on the right side of a split vat or in
a full vat that has a different setpoint other than the current
vat temperature.
E02
M3000 ONLY
REMOVE DISCARD (Left)
A product cook is started on the right side of a split vat or in
a full vat that has a different setpoint other than the current
vat temperature.
E03
ERROR TEMP PROBE FAILURE
TEMP Probe reading out of range.
E04
HI 2 BAD
High limit reading is out of range.
E05
HOT HI 1
High limit temperature is more than 410°F (210°C), or in
CE countries, 395°F (202°C).
E06
HEATING FAILURE
A component has failed in the high limit circuit such as
controller, interface board, contactor or open-high limit.
E07
ERROR MIB SOFTWARE
Internal MIB software error.
E08
ERROR ATO BOARD
MIB detects ATO board connection lost; ATO board failure.
E09
ERROR PUMP NOT FILLING
Oil not returning to vat quickly. Possible problems: dirty
pad, bad or missing O-rings, tripped or defective fi lter
pump, actuators or linkage.
E10
ERROR DRAIN VALVE NOT OPEN
Drain valve failed to open; valve’s position is unknown.
E11
ERROR DRAIN VALVE NOT CLOSED
Drain valve failed to close; valve’s position is unknown.
E12
ERROR RETURN VALVE NOT OPEN
Return valve failed to open; valve’s position is unknown.
E13
ERROR RETURN VALVE NOT CLOSED
Return valve failed to close; valve’s position is unknown.
E14
ERROR AIF BOARD
MIB detects AIF missing; AIF board failure.
E15
ERROR MIB BOARD
Cooking controller detects MIB connections lost; check
software version on each controller. If versions are missing,
check CAN connections between each controller; MIB
board failure.
E16
ERROR AIF PROBE
AIF RTD reading out of range.
E17
ERROR ATO PROBE
ATO RTD reading out of range.
E18
Not Used
E19
CAN TX FULL©
Connection between controllers lost.
E20
INVALID CODE LOCATION
SD card removed during update.
E21
FILTER PAD/PAPER PROCEDURE ER-
ROR (Change Filter Pad or Paper)
25 hour timer has expired or dirty fi lter logic has activated.
E22
OIL IN PAN ERROR
The MIB has detected oil may be in the pan.
E23
CLOGGED DRAIN (Gas)
Vat did not empty during fi ltration.
E24
OIL RETURN (level) SENSOR FAILED
(Gas)
Oil return sensor may have failed.
E25
RECOVERY FAULT
Recovery time exceeded maximum time limit.
E26
M3000 ONLY
RECOVERY FAULT CALL SERVICE
Recovery time exceeded maximum time limit for two or
more cycles.
E27
LOW TEMP ALARM
Oil temperature has dropped lower than 15°F (8°C) in idle
mode or 45°F (25°C) in cook mode.
E28
FilterQuick3000 ONLY
HIGH TEMP ALARM
Oil temperature has risen 40°F (22.2°C) higher than
setpoint. If temperature continues to rise, the high limit
will shut the power off at 425°F (218°C) Non-CE or 395°F
(202°C) CE.
LOV/FQ Error Codes
Summary of Contents for FilterQuick Series
Page 9: ...High Efficiency Gas 2 4 H55 CM 3 5 Controller Blower Gas Valve Igniter...
Page 11: ...High Efficiency Gas 2 6 OCF Blower Gas Valve Spark Module Igniter Gas Valve...
Page 136: ...5 33 Touchscreen Equipped Fryers FQ4000 Menu Tree Taco Bell...
Page 137: ...5 34 Touchscreen Equipped Fryers FQ4000 Information Statistics Menu Tree Taco Bell...
Page 140: ...5 37 Touchscreen Equipped Fryers FQ4000 Menu Tree Taco Bell...
Page 141: ...5 38 Touchscreen Equipped Fryers FQ4000 Information Statistics Menu Tree Taco Bell...
Page 143: ...5 40 Touchscreen Equipped Fryers M4000 Information Statistics Menu Tree...
Page 145: ...5 42 Touchscreen Equipped Fryers M4000 Information Statistics Menu Tree...
Page 161: ...Charts and Tables 6 4 Reading Model Numbers 7 LQ WKLV SRVLWLRQ 7RXFKVFUHHQ...
Page 169: ......