5-17
Touchscreen-Equipped Fryers
Error Log Codes
To access the error log, press the home button. Press the service button. Press the manager button. Enter 1656 and
press the check button. Press the E-log button. The ten most recent errors are listed from top to bottom, with the top
error being the most recent error. A “G” indicates a global error such as a filtration error. Side-specific errors in split
vats are indicated by L for left or R for right. Pressing the left down arrow allows scrolling through the errors. If no
errors are present the screen will be blank
.
Code
ERROR MESSAGE
EXPLANATION
E13
TEMPERATURE PROBE FAILURE
TEMP Probe reading out of range
E16
HIGH LIMIT 1 EXCEEDED
High limit temperature is past more than 410°F (210°C), or in
CE countries, 395°F (202°C)
E17
HIGH LIMIT 2 EXCEEDED
High limit switch has opened.
E18
HIGH LIMIT PROBLEM
DISCONNECT POWER
Vat temperature exceeds 460°F (238°C) and the high limit has
failed to open. Immediately disconnect power to the fryer
and call service.
E19
HEATING FAILURE – XXX F or XXX C
Heating Control latch circuit failed.
Heat Contactor failed to latch.
E25
HEATING FAILURE - BLOWER
The air pressure switch(s) failed to close.
E27
HEATING FAILURE - PRESSURE SWITCH - CALL SERVICE
The air pressure switch has failed closed.
E28
HEATING FAILURE – XXX F or XXX C
The fryer has failed to ignite and has locked out the ignition
module.
E29
TOP OFF PROBE FAILURE - CALL SERVICE
ATO RTD reading out of range
E32
DRAIN VALVE NOT OPEN - FILTRATION AND TOP OFF
DISABLED - CALL SERVICE
Drain valve was trying to open and confirmation is missing
E33
DRAIN VALVE NOT CLOSED - FILTRATION AND TOP OFF
DISABLED - CALL SERVICE
Drain valve was trying to close and confirmation is missing
E34
RETURN VALVE NOT OPEN - FILTRATION AND TOP OFF
DISABLED - CALL SERVICE
Return valve was trying to open and confirmation is missing
E35
RETURN VALVE NOT CLOSED - FILTRATION AND TOP OFF
DISABLED - CALL SERVICE
Return valve was trying to close and confirmation is missing
E36
VALVE INTERFACE BOARD FAILURE - FILTRATION AND
TOP OFF DISABLED - CALL SERVICE
Valve Interface Board connections lost or board failure.
E37
AUTOMATIC INTERMITTENT FILTRATION PROBE FAILURE
- FILTRATION DISABLED - CALL SERVICE
AIF (VIB Probe) RTD reading out of range.
E39
CHANGE FILTER PAD
25-hour timer has expired or dirty filter logic has activated.
E41
OIL IN PAN ERROR
The system detects that oil may be present in the filter pan.
E42
CLOGGED DRAIN (Gas)
Vat did not empty during filtration
E43
OIL SENSOR FAILURE - CALL SERVICE
Oil level sensor may have failed.
E44
RECOVERY FAULT
Recovery time exceeded maximum time limit.
E45
RECOVERY FAULT – CALL SERVICE
Recovery time exceeded maximum time limit for two or more
cycles.
Reset the error code by going to: HOME -> SERVICE
-> SERVICE ->3000-> TECH MODE -> RESETS -> RECOVERY
FAULT CALL SERVICE -> YES.
E46
SYSTEM INTERFACE BOARD 1 MISSING - CALL SERVICE
SIB board 1 connection lost or board failure.
E51
DUPLICATE BOARD ID - CALL SERVICE
Two or more controllers have the same location ID.
E52
USER INTERFACE CONTROLLER ERROR - CALL SERVICE
The controller has an unknown error.
E53
CAN BUS ERROR - CALL SERVICE
Communications are lost between boards.
E55
SYSTEM INTERFACE BOARD 2 MISSING - CALL SERVICE
SIB board 2 connection lost or board failure.
E62
SLOW HEATING FAILURE XXXF OR XXXC - CHECK ENERGY
SOURCE - CALL SERVICE
The vat is not heating properly.
E63
RATE OF RISE
Rate of rise error occurred during a recovery test.
E64
FILTRATION INTERFACE BOARD FAILURE - FILTRATION
AND TOP OFF DISABLED - CALL SERVICE
Filtration Interface Board connections lost or board failure.
E65
CLEAN OIB SENSOR – XXX F OR XXX C - CALL SERVICE
Gas -The oil is back sensor does not detect oil. Clean optional
oil sensor.
E66
DRAIN VALVE OPEN – XXXF OR XXXC
Drain valve is opened during cooking.
E67
SYSTEM INTERFACE BOARD NOT CONFIGURED - CALL
SERVICE
Controller is turned on when the SIB board is not configured.
Summary of Contents for FilterQuick Series
Page 9: ...High Efficiency Gas 2 4 H55 CM 3 5 Controller Blower Gas Valve Igniter...
Page 11: ...High Efficiency Gas 2 6 OCF Blower Gas Valve Spark Module Igniter Gas Valve...
Page 136: ...5 33 Touchscreen Equipped Fryers FQ4000 Menu Tree Taco Bell...
Page 137: ...5 34 Touchscreen Equipped Fryers FQ4000 Information Statistics Menu Tree Taco Bell...
Page 140: ...5 37 Touchscreen Equipped Fryers FQ4000 Menu Tree Taco Bell...
Page 141: ...5 38 Touchscreen Equipped Fryers FQ4000 Information Statistics Menu Tree Taco Bell...
Page 143: ...5 40 Touchscreen Equipped Fryers M4000 Information Statistics Menu Tree...
Page 145: ...5 42 Touchscreen Equipped Fryers M4000 Information Statistics Menu Tree...
Page 161: ...Charts and Tables 6 4 Reading Model Numbers 7 LQ WKLV SRVLWLRQ 7RXFKVFUHHQ...
Page 169: ......