10.4
Reversing flap lever
To reverse the direction of the flap lever
1.
Open the
M
IXERS
menu
2.
Skip to CH 20 (‘Flap’)
3.
Change weight from +25 to -25
10.5
Rates
There is no dedicated ‘rates’ or ‘expo’ menu in OpenTx. Instead, you add extra lines in the
INPUTS
menu
.
Here are examples showing triple rates (a) linked to flight-modes and (b) selected by switch:
(a) Aileron rate by flightmode
: Thermal (FM0) 40%; Power mode (FM2) 30%; all other flight modes: 60%
(b) Aileron rate by switch
: SB↓ 40%; SB↑80%; default (SB― ): 60%
How OpenTx handles inputs
:
Starting with the first line, OpenTx extracts the flight mode and switch
values, and compares them with the current transmitter state. If a match is found, the line becomes active
and OpenTx uses those rate/expo values. If there is no match, OpenTx advances to the next line and
repeats the test. And so on till either a match is found or the end of the list is reached.
Note 1:
If no match is found, the control will be inoperative
. As a defence against this possibility, the last
line should be a ‘CATCHALL’ with
all flightmodes and no switch
.
Note 2:
If both flightmode and switch are specified in the same line, both must match for the line to be
active.
10.6
Altering minimum SH duration for motor arm/kill
In order to arm or kill the motor,
SH
must be pulled for a certain minimum duration.
To increase or decrease the minimum duration:
1.
Open the
LOGICAL SWITCHES
menu
2.
To alter arming duration, edit L8. Default = 1.2 secs
3.
To alter the kill duration, edit L11. Default = 1.1 secs
Note:
For reliable operation, the kill duration must be less than the arming duration.