38
-
Check the coolant level and purity.
-
If the coolant level is below the „min“ mark, top up the coolant.
Note!
Use only Original Fronius coolant (40,0009,0046) for filling the cooling
unit. We do not recommend other coolants, due to their electrical conductivity
and insufficient compatibility.
-
Check the return for dirt and clean if necessary
-
If available: Check water filter and flow monitor are functioning correctly, check for
dirt, and clean them or replace filter pipe
-
Dismantle machine side panels and clean inside of machine with dry reduced
compressed air.
Note!
Risk of damage to electronic components. Do not bring the air nozzle too
close to the electronic components.
-
If a lot of dust has accumulated, clean the water cooler as well.
Dispose of in accordance with the applicable national and local regulations.
-
Replace coolant
-
Dispose of used coolant properly.
Important!
Coolant must not be disposed of in the normal sewerage system!
Note!
Use only Original Fronius coolant (item no. 40,0009,0046) for refilling the
cooling unit.
Caution!
Risk of scalding from excessively hot coolant. Only check the water
connections when the coolant has cooled sufficiently.
Caution!
Risk of scalding from excessively hot coolant. Only check the water
connections when the coolant has cooled sufficiently.
Caution!
Risk of scalding from excessively hot coolant. Only check the water
connections when the coolant has cooled sufficiently.
Every week
Every 2 months
Every 6 months
Every 12 months
Disposal
With regard to cooling units, the „General Delivery and Payment Conditions“ according
to the price list only apply under the following prerequisites:
-
Max. 8 h / day operation (operation for a single shift)
-
Exclusive use of Fronius coolant (item 40,0009,0046 or 40,0009,0075)
-
Regular maintenance and regular change of coolant
Validity of „Gene-
ral Delivery and
Payment Conditi-
ons“