Analog Outputs
Welding voltage
(Welding voltage)
- Group Output /
Analog Output
As described below, the current welding voltage actual value can be output on a Digital
Interface or an Analog Interface.
Digital Interface:
-
During the welding process, the current welding voltage actual value will be out-
put as a value between 0 - 65,535 (UINT 16).
-
The welding voltage set value is output when idling.
-
The Hold value is output immediately after welding.
Value range
Designation
Min./max. possible value
0
Welding voltage
0 V (set value/actual value/Hold value)
32,767
Welding voltage
327.67 V (set value/actual value/Hold value)
Additional information for TWIN systems:
The digital actual value is output separately for both power sources.
Analog Interface:
-
During the welding process, the current welding voltage actual value will be out-
put as a value between 0 - 10 V.
-
The welding voltage set value is output when idling.
-
The Hold value is output immediately after welding.
Value range
Designation
Min./max. possible value
0 V
Welding voltage
0 V (set value/actual value/Hold value)
10 V
Welding voltage
100 V (set value/actual value/Hold value)
Additional information for TWIN systems:
The analog actual value is not output on TWIN systems.
Welding current
(Welding current)
- Group Output /
Analog Output
As described below, the present welding current actual value can be output on a Digital
Interface or an Analog Interface.
Digital Interface:
-
During the welding process, the present welding current actual value will be out-
put as a value between 0 and 65,535 (UINT 16).
-
The welding current command value is output when idling.
-
The Hold value is output immediately after welding.
Value range
Designation
Min./max. possible value
0
Welding current
0 A (set value/actual value/Hold value)
32,767
Welding current
3276.7 A (set value/actual value/Hold value)
Additional information for TWIN systems:
The digital actual value is output separately for both power sources.
Analog Interface:
-
During the welding process, the present welding current actual value will be out-
put as a value between 0 - 10 V.
-
The welding current command value is output when idling.
-
The Hold- value is output immediately after welding.
37
EN-US