![Fronius TPS/i User Information Download Page 36](http://html1.mh-extra.com/html/fronius/tps-i/tps-i_user-information_2339420036.webp)
Twin synchroniz-
ation active -
Single Bit
The signal indicates that the synchronization between the two power sources is active.
System not ready
- Single Bit
This signal indicates whether the welding system is ready for use:
-
This signal is Low if there are no error messages in the welding system (all error
sources must be eliminated for the signal to change to Low)
-
This signal is High as soon as a component of the welding system outputs an error
message
Examples of when this signal changes to High:
-
A component of the welding system performs an update
-
Emergency stop
-
In conjunction with wire sensors (ring sensor, sensor on wire drum, etc.), for
example, errors 16828, 16837, 16838
If the following exceptions occur, the signal remains Low despite the error messages:
-
The Robot ready signal is Low
-
During the welding process, a welding torch detection problem occurs (BID error)
Notification (Noti-
fication) - Single
Bit
-
The signal is High when the power source issues a notification.
-
Notifications can arise, for example, due to set process limits, external sensors, etc.
-
The signal automatically interrupts the welding process
-
Operation of the power source is possible while the signal is High
-
The signal remains High until the reason for the notification has been resolved.
-
The signal automatically changes to Low, as soon as the reason for the notification
has been eliminated
Additional information for TWIN systems:
The signal is set to High as soon as one of the two power sources issues a notification.
36