95
Fig.9
- Push the mains cable into the housing
- Wind the mains-cable earthing
conductor (87) onto the ferrite core
(88), with 5 windings
- Carefully pull the mains cable a short
way out of the housing, until the ferrite
core (88) with the wound-on earthing
conductor (87) can be stowed away
well
(87)
(88)
Mounting the
mains cable
- At the rear of the machine, tighten the
M5x25 - TX20 screws (34) for the
mains-cable strain relief device with a
torque of 1.5 Nm
(34)
Fig.10
Fig.11
- Thread the mains-cable earthing
conductor (87) through the air-guide
film (49) and plug it onto the heat sink
(87)
(49)
- On the mains leads L - brown (84) and
N - blue (85), push the insulating
sleeves (86) onto the flat-pin plugs
Fig.12
(84)
(85)
(86)