31
Measuring and testing equipment, tools
-
Oscilloscope
-
Multimeter
with diode-testing function
-
Shunt
(measuring range: up to 180 A)
-
Power resistor
(160 mOhm / P > 3.14 kW)
-
Power resistor
(4 Ohm / P > 400 W)
-
Test unit for PE conductor test
(cross-sectional area of PE conductor: 1.5 mm²)
-
Test unit for insulation test
-
Recommended: Measuring circuit for testing the open-circuit voltage
(see the
section headed “Measuring, inspection and adjustment jobs”)
Measuring and
test equipment
History
No modifications have yet been made to the TP 1500 series.
Modification
Tools and
appliances
Designation
(1) Manual torque screwdriver 1 to 6 Nm
(2) Bit insert TX 20, for torque screwdriver
(3) Bit insert
hexagon-socket, width-across 3, for torque screwdriver
(4) Molex extractor tool
(5) Grinding paper (grain P 500 or finer)
(6) Contact spray
(7) Socket spanner holder with 1/4’’ external hexagonal-socket drive and 1/4’’ external
square-socket drive, to fit torque screwdriver
(8) Socket spanner insert - width-across 7 - with 1/4 ’’ internal square-socket drive
Note!
Observe the calibration intervals specified by your QM System for the
measuring and testing equipment and tools that are used.
Fig.1Tools and appliances
General remarks
(1)
(2)
(4)
(5)
(6)
(7)
(8)
(3)