14
All the relevant data for the TP 1500
power source may be found on the rating
plate.
Legend:
(1) Identification
(2) Data regarding weld process
(3) Data regarding power supply
Rating plate
(1)
(2)
(3)
The “Identification” section of the rating
plate contains the manufacturer’s symbol
and the place of origin, together with the
type (model), article number and serial
number of the power source. The symbol
for the functional principle of the power
source, and the Standards with reference
to which it was developed, produced and
given final inspection & testing, are also
shown here.
Identification
(1)
(2)
(3)
(4)
(6)
(5)
Legend:
(1) Manufacturer’s symbol, place of origin
(2) Type designation (trade name) of the power source
(3) Article number of the power source
(4) Serial number of the power source “XXYYZZZZ” (8-digit)
(Code: XX=year, YY=calendar week, ZZZZ=serial number)
(5) Statement of the Standards governing the development, manufacture and final testing & inspection of the power
source
(6) Symbol for the functional principle of the power source according to the inverter principle (see Section “4. General
basics - Functional principle”)
The “Weld-process data” section gives
information on the weld process for which
the power source is intended (here = rod-
electrode welding and TIG welding with
contact ignition).
This section also states the welding-
amperage range, the maximum
permissible welding amperage (for the
respective duty cycle) and the respective
output voltages.
Fig.1
Rating plate on the TP 1500 power source
Fig.2
“Identification” section
Data regarding
weld process
Fig.3
“Weld-process data” section
(7)
(1)
(2)
(3)
(5)
(6)
Technical data - Rating plate
(4)
Legend:
(1) Adjustable welding-amperage range with the relevant values for the output voltage
(2) Symbol for the type of welding current (here: direct current = DC)
(3) First weld process for which the power source is intended
(here = rod-electrode welding)
(4) Second weld process for which the power source is intended
(here = TIG welding with contact ignition)
(5) Maximum permissible values for welding current and the respective welding voltage
- at the stated ambient temperature (here: 40 °C) and
- for the respective duty cycles (here: 25 %, 35 % and 100 %)
(6) Rated open-circuit voltage (here: 92 V)
(7) Symbol for power sources that are suitable for welding in conditions of increased electrical hazard