86
- Cut through the cable binder (33)
- Unplug the 2-pole Molex plug (40) from
the LCA15 board
- Undo the M4x14-TX20 screw (31)
- Detach the temperature sensor (9)
(33)
(40)
Fig.3
(31)
(9)
(79)
Fig.4
(33)
(40)
Fig.5
- Plug the 2-pole Molex plug (40) onto
the LCA15 board
- Fix the cable harness for the 2-pole
Molex plug (40) and the 10-pole Molex
plug (41) with the cable binder (33)
- Mount the temperature sensor (9) and the suppressor circuit (79) using a M4x14-
TX20 screw (31)
- Tighten the M4x14-TX20 screw (31) with a torque of 2 Nm (Fig.4)
Fitting the
temperature
sensor
Removing the
temperature
sensor
(41)