6
Push forward and hold the torch trigger
Release the torch trigger
Fig. 5c
Functional sequence in special 4-step mode - Variant IV
Pull back and release the torch trigger
I
S
I
H
I
E
I
t
Pull back and hold the torch trigger
Release the torch trigger
I
H
Start
of
cycle
Gas
pre-flow
time
Current
rises
via
upslope
Current
drops
via
downslope
Gas
post-flow
time
End
of
welding
Crater-fill
current
Arc
ignites
with
start-arc
current
I
S
Welding
with
pre-set
main
current
I
H
Current
rises
via
upslope
Welding
with
pre-set
main
current
I
H
Start
of
cycle
Gas
pre-flow
time
Current
rises
via
upslope
Current
drops
via
downslope
Gas
post-flow
time
End
of
welding
Crater-fill
current
Pull back and hold the torch trigger
Release the torch trigger
Release the torch trigger
Arc
ignites
with
start-arc
current
I
S
Welding
with
pre-set
main
current
I
H
Fig. 5d
Functional sequence in special 4-step mode - Variant V
Push forward and hold the torch trigger
I
S
I
H
I
E
I
t
Current-rise
when
torch
trigger
is
pushed
forward
Current-drop
when
torch
trigger
is
pushed
forward
Welding
with
decreased
main
current
I
H
Push forward and hold the torch trigger
Release the torch trigger
Pull back and hold the torch trigger
Release the torch trigger
Welding
with
increased
main
current
I
H
Variant V (Fig. 5d) allows the welder to raise and lower the welding
current without an Up/Down torch.
The longer the torch-trigger rocker switch is pushed forward
during welding, the more the welding current is increased (up to
maximum).
After the welder releases the torch trigger, the welding current
remains constant. The longer the torch trigger is pushed forward
once again, the further the welding current is reduced.
Diagram showing intermediate lowering
LED INDICATOR FOR 2-STEP MODE
2-step mode
(Fig.6)
-
is activated from TIG torch trigger
-
is mainly used for tack welding
-
In the "PRESETTINGS LEVEL ---" program-level, parame-
ter TIG, the setting for StS must be set to "OFF"
Functional sequence:
1. Pull back and hold the torch trigger
-
Gas pre-flow time elapses
-
Arc ignites at the pre-set value for start-arc current I
S
(with HF
ignition: HF cuts out automatically after ignition)
-
After ignition, the welding current rises via the internally pre-
set upslope to the welding-current value I
H
-
LED lights up
2. Release the torch trigger
-
Arc goes out
(with or without the current being lowered)
-
Internally pre-set gas post-flow time elapses
When the remote-control pedal unit TR 52mc is used, the
machine automatically switches over to 2-step mode.
Start
of
cycle
Gas
pre-flow
time
Current
rises
via
upslope
End
of
welding,
via
downslope
to
crater-fill
current
I
E
Gas
post-flow
time
Pull back and hold the torch trigger
Release the torch trigger
Arc
ignites
with
start-
arc
current
I
S
Welding
with
pre-set
main
current
I
H
Fig. 6
Functional sequence in 2-step mode
I
H
I
t
Summary of Contents for MagicWave 2600
Page 2: ......
Page 4: ......
Page 16: ...ud_fr_st_sv_00466 022003 XII ...
Page 40: ......
Page 52: ...ud_fr_st_sv_00467 022003 XII ...
Page 76: ......
Page 88: ...ud_fr_st_sv_00468 022003 XII ...