11. REMOTE CONTROL UNIT DOES
NOT WORK
(all other functions are OK)
Remote control cable is not properly
connected
Plug in the remote control cable the right
way round,
Change the remote control socket
10-pole remote control socket is faulty
Fuse F1 on FK 26 cooling-unit board
(No 4.070.532)
is faulty
Change the fuse
12. FK 2600 COOLING UNIT DOES NOT
FUNCTION
Operational readiness
indicator on cooling unit is not lit up
Remote control unit or cable is faulty
Change the remote control unit or cable
Warning!
Where fuses need to be changed, they must be replaced by fuses of the same rating. No warranty claims will be
accepted in respect of damage caused by the use of too high a raiting of fuse!
REMEDY
CAUSE
FAULT