63
EN
Special 4-step
mode:
variant 1
Variant 1 of special 4-step mode is activated, when the special 4-step (SFS) set-up param
-
eter
-
is set to "1".
Briefly pull back the torch trigger to start intermediate lowering to the specified reduced cur
-
rent I
2
. Briefly pull back the torch trigger a second time, to restore the main current I
1
.
Special 4-step mode: Variant 1
Special 4-step
mode:
variant 2
Variant 2 of the special 4-step mode is activated when the special 4-step SFS set-up pa
-
rameter
-
is set to "2“.
Intermediate lowering takes place in variant 2 on the basis of the selected slope values -
downslope t
down
and upslope t
up
:
-
Push forward and hold the torch trigger: the welding current continuously drops at the
set downslope value until it reaches the specified reduced current I
2
. It remains at the
reduced current value I
2
until the torch trigger is released.
-
When the torch trigger is released: the welding current rises at the specified upslope
value until it reaches the main current value I
1
.
Special 4-step mode: Variant 2
I
t
I
1
GPr
I
S
t
down
I
E
G-L
G-H
I
1
I
2
t
up
I
t
I
1
GPr
I
S
t
down
I
E
G-L
G-H
I
1
I
2
t
up
Summary of Contents for MagicWave 1700 Job
Page 2: ...2...
Page 18: ...18...
Page 19: ...General information...
Page 20: ......
Page 25: ...Control elements and connections...
Page 26: ......
Page 46: ...46...
Page 47: ...Installation and commissioning...
Page 48: ......
Page 57: ...Welding...
Page 58: ......
Page 86: ...86...
Page 87: ...Setup settings...
Page 88: ......
Page 121: ...Troubleshooting and maintenance...
Page 122: ......
Page 131: ...Appendix...
Page 132: ......
Page 146: ...146...
Page 147: ...147 EN...