109
EN
AC/polarity reversal set-up menu - level 2
General
This set-up menu is only available with MagicWave power sources.
Opening the AC/
polarity reversal
set-up menu - lev
-
el 2
Changing weld
-
ing parameters
Exiting from the
AC/polarity rever
-
sal set-up menu -
level 2
Welding parame
-
ters in the AC/po
-
larity reversal set-
up menu - level 2
"Minimum" and "maximum" are used for setting ranges that differ according to power
source, wire-feed unit, welding program, etc.
Open the AC/polarity reversal set-up menu
Select "2nd" welding parameter
Press and hold the Store button
Press the Process button
The power source is now in the set-up menu - level 2 AC/polarity reversal.
The last welding parameter selected is displayed.
1
2
3
4
Use the left or right parameter selection button to select the welding pa
-
rameter that you want to change
Use the adjusting dial to change the welding parameter value
1
2
Press the Store button
The power source is now in the AC/polarity reversal set-up menu
To exit from the AC/polarity reversal set-up menu, press the Store button
again
1
2
PoS
Positive half wave
Unit
-
Setting range
tri / Sin / rEc / OFF
Factory setting
OFF
tri
Triangular waveform
Sin
Sine ... sinusoidal waveform (standard setting for a low-noise,
stable arc)
rEc
Rectangular waveform with decreased edge steepness, for re
-
ducing noise levels compared to those that occur with the 100%
rectangular waveform
OFF
100% rectangular waveform (stable but loud arc)
Summary of Contents for MagicWave 1700 Job
Page 2: ...2...
Page 18: ...18...
Page 19: ...General information...
Page 20: ......
Page 25: ...Control elements and connections...
Page 26: ......
Page 46: ...46...
Page 47: ...Installation and commissioning...
Page 48: ......
Page 57: ...Welding...
Page 58: ......
Page 86: ...86...
Page 87: ...Setup settings...
Page 88: ......
Page 121: ...Troubleshooting and maintenance...
Page 122: ......
Page 131: ...Appendix...
Page 132: ......
Page 146: ...146...
Page 147: ...147 EN...