115
EN
Rod electrode setup menu: level 2
Opening the rod
electrode set-up
menu level 2
Changing weld
-
ing parameters
Exiting the rod
electrode set-up
menu - level 2
Welding parame
-
ters in the rod
electrode setup
menu - level 2
Open the rod electrode set-up menu
Select "2nd" welding parameter
Press and hold the Store button
Press the Mode button
The power source is now in the rod electrode set-up menu - level 2. The
last welding parameter selected is displayed.
1
2
3
4
Use the left or right parameter selection button to select the welding pa
-
rameter that you want to change
Use the adjusting dial to change the welding parameter value
1
2
Press the Store button
The power source is now in the rod electrode set-up menu
To exit from the rod electrode set-up menu, press the Store button again
1
2
r
r (resistance) - welding circuit resistance (in mOhm)
see "Measuring the welding circuit resistance r"
L
L (inductivity) - Welding circuit inductivity (in microhenry)
see "Displaying welding circuit inductivity L"
ASt
Anti-stick
Unit
-
Setting range
ON / OFF
Factory setting
ON
As the arc becomes shorter, the welding voltage may drop so far that the rod electrode
will tend to stick. This may also cause the rod electrode to burn out.
Electrode burn-out is prevented by activating the anti-stick function. If the rod electrode
begins to stick, the power source immediately switches the welding current off. After the
rod electrode has been detached from the workpiece, the welding process can be contin
-
ued without any problems.
Summary of Contents for MagicWave 1700 Job
Page 2: ...2...
Page 18: ...18...
Page 19: ...General information...
Page 20: ......
Page 25: ...Control elements and connections...
Page 26: ......
Page 46: ...46...
Page 47: ...Installation and commissioning...
Page 48: ......
Page 57: ...Welding...
Page 58: ......
Page 86: ...86...
Page 87: ...Setup settings...
Page 88: ......
Page 121: ...Troubleshooting and maintenance...
Page 122: ......
Page 131: ...Appendix...
Page 132: ......
Page 146: ...146...
Page 147: ...147 EN...