108
Effect of the AC parameters on the waveshape
(1)
Balance
(2)
AC frequency
(3)
AC current offset
*)
Factory setting: 20% shift to the ne
-
gative
Io
AC current offset
Unit
%
Setting range
-70 to +70
Factory setting
0
+70
distant arc with shallow heat input
-70
narrow arc, deep heat input, faster welding speed
2nd
set-up menu - level 2: second level of the set-up menu
I (A)
t (s)
(3)
-70%
+70%
+
-
0
(1)
+
-
+
-
t (s)
t (s)
I (A)
I (A)
(2)
0
+5
-5
60 Hz
120 Hz
35%
50%
15%
*)