125
EN
tSt | xxx
Note: xxx stands for a temperature value
Cause:
Overtemperature in the power source control circuit
Remedy:
Allow power source to cool down
Err | 049
Cause:
Phase failure in power supply
Remedy:
Check the mains fuse, the mains lead and the mains plug
Err | 050
Cause:
Indirect symmetry error
Remedy:
Contact After-Sales Service
Err | 051
Cause:
Mains undervoltage: The mains voltage has dropped below the lower limit of
the tolerance range (see section "Technical data")
Remedy:
Check the mains voltage
Err | 052
Cause:
Mains overvoltage: The mains voltage has exceeded the upper limit of the tol
-
erance range (see section "Technical data")
Remedy:
Check the mains voltage
no | IGn
Cause:
"Ignition time-out" function is active; current did not start flowing before the
length of wire specified in the set-up menu had been fed. The power source
safety cut-out has tripped.
Remedy:
Press the torch trigger repeatedly; clean the workpiece surface; if necessary,
increase the time until the safety cut-out is triggered in the set-up menu: level
2
Err | PE
Cause:
The earth current watchdog has triggered the safety cut-out of the power
source.
Remedy:
Switch off the power source, wait for 10 seconds and then switch it on again.
If you have tried this several times and the error keeps recurring, contact Af
-
ter-Sales Service.
Err | IP
Cause:
Primary overcurrent
Remedy:
Contact After-Sales Service
Err | bPS
Cause:
Fault in power module
Remedy:
Contact After-Sales Service
dSP | Axx
Cause:
Fault in the central control and regulation unit
Remedy:
Contact After-Sales Service
dSP | Cxx
Cause:
Fault in the central control and regulation unit
Remedy:
Contact After-Sales Service
Summary of Contents for MagicWave 1700 Job
Page 2: ...2...
Page 18: ...18...
Page 19: ...General information...
Page 20: ......
Page 25: ...Control elements and connections...
Page 26: ......
Page 46: ...46...
Page 47: ...Installation and commissioning...
Page 48: ......
Page 57: ...Welding...
Page 58: ......
Page 86: ...86...
Page 87: ...Setup settings...
Page 88: ......
Page 121: ...Troubleshooting and maintenance...
Page 122: ......
Page 131: ...Appendix...
Page 132: ......
Page 146: ...146...
Page 147: ...147 EN...