Installation
Assembly work
Page 24
M1010108_en
s
3
U
Dismantle the flange by undoing the screws
U
Turn the flange plate and the insulating plate 180°
U
Reassemble the flange
Assembly work on boiler
U
Fit the geared motor and seal to the
flange as illustrated using the
hexagonal screws provided
Do not tighten the screws yet
U
Remove the sticky tape and key-way
safety device from the shaft stub on
the ash screw
U
Thread the ash screw through the
gears
Ensure that the ash screw is
threaded into the gear key-way.