Installation
Assembly work
Page 26
M1010108_en
s
3
3.3.6
Installing the combustion chamber overpressure sensor
If combined with a pellet suction system
the combustion chamber overpressure
sensor is installed in the stoker duct
À
See assembly instructions for pellet
suction system
On the grate shaft side:
U
Remove the pre-cut perforation in the
centre of the insulating side panel
U
File rough edges using a half-round
file and remove burrs
U
Removing the blind plug
U
Screw in extension and brass casing
U
Insert combustion chamber
overpressure monitor into the
extension and secure with locking
screw
3.3.7
Fitting switch cabinet and cable ducts
NOTICE
Fit bracket and switch cabinet on the stoker side as the length of the cables
for the individual units are measured for this side.
U
Remove pre-fitted cover plate from
insulating side panel
U
Attach spacer washer to threaded
bolts
U
Position bracket for switch cabinet at
threaded bolts
U
Ensure that the bracket is horizontal
when tightening