4.5.23 Assembling the burner pivoting mechanism (optional)
❒ Mount the hinged joint to fix the mechanism in place (A)
➥ This hinged joint needs to be mounted before the insulating side panels!
E
❒ Mount the intermediate hinge (B) onto the hinge joint (A) using a long bolt (D)
❒ Mount the end hinge (C) onto the intermediate hinge (B) using a long bolt (D)
❒ Mount the blind flange (E) and oil burner flange (F) onto the end hinges (C) using
short bolts (G)
❒ Mount the adapter flange for the oil burner (H)
❒ Mount the limit switch (I) or burner flange with bracket onto the drill holes in the
insulation
4
Assembly
Installing the boiler
58