![Froling Turbomat TM 400 Installation Instructions Manual Download Page 55](http://html1.mh-extra.com/html/froling/turbomat-tm-400/turbomat-tm-400_installation-instructions-manual_2338738055.webp)
4.5.21 Assembling the EOS drive with function monitoring
❒ Attach the motor mount (1) to the threaded bolts in the heat exchanger and fix in
place using 4 M8 safety nuts
❒ Mount the drive wheel (2) in the geared motor
❒ Mount the geared motor with the bracket for function monitoring (3)
❒ Fix the function monitoring (4) to the bracket
❒ Fit the cover plates
4.5.22 Assembling the insulated doors and covers
❒ Place both the front insulating covers on top of the combustion chamber
Assembly
4
Installing the boiler
Installation Instructions Turbomat TM 400-500 | M0690213_en
55