10.2.6.
Condensation formed on the frame lids
see
par.
see
par.
par.
see
par.
see
par.
see
par.
Condensation on the cell lids appears when the door gasket does not seal or the “R1” frame resistance
connected to terminal 17 of the power board
1.
Check that the door is correctly aligned,
→
otherwise adjust it
2.
Check that the door gasket is not damaged, otherwise replace it with a new one
Inform the Customer that the gasket must be cleaned monthly and changed once a year by an
authorised service centre
→
see “Routine maintenance” sheet
3.
Check that the “R1” frame resistance works
Access the machine electrical panel (when removing the front panel on 5 baking tray models, place a
magnet on the door microswitch to prevent the
Door Open Alarm
Make sure that the evaporator fan works
Using a current clamp, check if there is absorption by the resistance
→
see wiring diagram
If there is no absorption
→
replace the frame resistance with a new one