Translation of the original instructions
19
FRIULINOX ALI GROUP S.R.L. A SOCIO UNICO
Via Treviso 4 - 33083 Taiedo di Chions (PN) - Italy
Service
M
an
u
al
Only for water-condensation units (WL)
Check the seal of the hydraulic connections
Indicate the condenser inlet water pressure
-
max. 4 (BAR)
…………..
Indicate the condenser inlet water
temperature -
max. 30(°C)
…………..
Calibrate the pressure valve at 13 - 15 bar
(WL version only)
Functional testing
Detect chamber temperature before starting
the heating cycle
…………..
Start a timed cooking cycle with chamber set
of 85°C
Show time (min) to reach 85°C in the
chamber
…………..
Bring the chamber to room temperature
(25/30°C), starting a timed +3°C blast chilling
cycle
Detect room temperature for cooling test
with chamber empty
…………..
Detect chamber temperature before starting
the cooling cycle
…………..
Start -18°C cycle in timed mode
Show time (min) to reach -35°C in the
chamber
(within max 50’)
…………..
Check door gasket seal
Illustrate the basic functions of the
equipment
Deliver user manuals, certificates, test
reports to the customer
Final test date
Name of technician who carried out the test
Customer name
Customer signature/stamp for acceptance