“go to
FRIULINOX ALI GROUPS.R.L. A SOCIO UNICO
38
Via Treviso,4 - 33083 Taiedo di Chions (PN) -Italy
Servi
ce
M
an
u
al
7.
Using a 7 mm wrench, loosen the nut that secures the
fan to the fan motor.
8.
Using a 4 mm wrench, loosen the four screws that
secure the fan motor to the conveyor.
9.
Remove the motor from the conveyor.
10.
Replace the fan motor, repositioning it on the conveyor.
11.
Reposition the fan, remembering to have the
arrow symbol outside (see image).
12.
Reposition the casing, closing the safety belt on the
protective casing.