2.8 Electrical safety
2.8.1 General information
n
The main switch separates the PULVERISETTE 14 premium line from
the mains on two poles.
n
Switch off the main switch if the PULVERISETTE 14 premium line is
idle for a longer period of time (e.g. overnight).
2.8.2 Protection against restart
In case of power failure during operation or after switching off with the
main switch, the housing cover is locked. The lock of the housing cover is
opened when the power returns. For safety reasons, however, the PUL-
VERISETTE 14 premium line does not restart.
2.8.3 Overload protection
The power consumption is permanently monitored. The monitor
switches off the motor after a continuous overload. To rectify the mal-
function, switch off the PULVERISETTE 14 premium line and remove the
blockage. Afterwards, switch the device back on and start the motor by
pressing the [ START ] button.
The device switches off if the drive motor becomes too hot.
The PULVERISETTE 14 premium line switches off when the drive is
blocked (
Ä
‘Repairs’ on page 39).
Safety information and use