ENGLISH - 8
and type 5G4 H07RN-F (for version 400 V), 5G6 H07RN-F (for version 220-230/3)
before connecting the machine to the mains.
•
Arrange the connection of the yellow-green wire to a good earth connection.
•
Put the machine metallic parts to earth by means
of the apposite equipotent fastening screw
located on the back under the frame and marked
by the symbol showed on the left.
•
Make sure that the water supply system is
provided with sufficient pressure for a correct
operation of the condensing system. A residual
pressure ranging between 1 bar and 3 bar is
considered suitable.
•
Connect the condensing water inlet hose to the
inlet showed in the picture by means of a rubber
hose Ø1/2”. Interpose a cut-off cock at the
operator’s reach.
•
Connect the condensing water outlet hose to the
outlet showed in the picture by means of a hose
connector Ø1/2” and bring it to the discharge.
•
Both for inlet and outlet connections it is
advisable to make use of linenized hoses suitable
to withstand pressures up to 10 bar and apposite
hose clamps DIN 3017.
•
The water outlet hose shall have a min.
inclination of 3 cm for each meter of length.
•
In case of water condensing it is necessary to
check that the water valve works correctly.
•
After both inlet and outlet hoses have been
connected, open the cut-off cock and make sure
that the discharge does not leak liquid when the
machine is not working. If this is the case, apply
to a qualified customer service.
•
After the main switch has been turned on press
the “
SEMIAUTOMATIC
” button to start up the
compressor motor. After a few seconds the
condensing water shall regularly come out of the
outlet hose end at a temperature of 35°C. Press
STOP
to stop the machine.
•
Verify the correct rotation direction of the mixer
motor: power the machine, press the “
MIXING
”
button and check through the hopper grid that the
mixer is rotating counter-clockwise. If the rotation
direction is not counter-clockwise exchange the
two wires of the feeder between themselves.
•
Press pushbutton
STOP
to stop the machine. Avoid idling the machine for a long time.
Summary of Contents for TAYLOR IC135 Series
Page 44: ...APPENDICI 2 8 2 Schema circuito frigorifero Refrigerant circuit diagram Kühlnetzplan ...
Page 47: ...5 APPENDICI C 135 s01 Tav 1 10 ...
Page 49: ...7 APPENDICI C 135 s01 Tav 2 10 ...
Page 51: ...9 APPENDICI C 135 s01 Tav 3 10 ...
Page 53: ...11 APPENDICI C 135 s01 Tav 4 10 ...
Page 55: ...13 APPENDICI C 135 s01 Tav 5 10 ...
Page 57: ...15 APPENDICI C 135 s01 Tav 6 10 ...
Page 59: ...17 APPENDICI C 135 s01 Tav 7 10 ...
Page 61: ...19 APPENDICI C 135 s01 Tav 8 10 ...
Page 63: ...21 APPENDICI C 135 s01 Tav 9 10 ...
Page 65: ...23 APPENDICI C 135 s01 Tav 10 10 ...
Page 67: ...NOTE NOTES BEMERKUNG ...