FRIGOMAT
GX2, GX4
16
EN
VI
APPENDICE / APPENDIX / SUPPLEMENT / 6tttttttt / ssikisis / sisisisi / ssjjsjsjsj
These operations are reserved exclusively for authorised from
the manifacturer and qualified personnel.
1
RESET
Carry out the Reset procedure when replacing an electronic board, to solve
any faults due to microprocessor blocking or when you want to recharge the
manufacturer's factory data, resetting any calibration.
The Reset procedure must only be carried out on the left hand panel of each
electronic card on which the reset is to be performed. The procedure
must not be repeated on the right hand key of the card.
To reset the electronic board, refer to the following instructions:
Power the machine.
With the machine at STOP,
press the STOP and AGITA-
TION/P keys simultaneously
and release them only after
the password identification
screen appears (fig.V/01).
Press the “STOP (▲)” “AGITATION (▼)”
and “PRODUCTION (◄►)” keys to enter
the password and then confirm it (fig.V/05).
If you do not know the password, contact the
Frigomat assistance service.
Once the password has been recognized, the software version installed on
the electronic card is displayed.
Press the STOP and PRO-
DUCTION / OK keys at the
same time and release only
after the PRG message
appears on the display
(fig.V/03).
Press the STOP key to exit the Reset procedure.
2
PROGRAMMING
For programming the electronic board, refer to the following instructions:
Make sure that the covers are assembled in the machine and in the closed
position.
Power the machine.
With the machine at STOP,
press the STOP and AGI-
TATION/P keys simulta-
neously and release them
only after the password
identification screen ap-
pears (fig.V/04).
Press the “STOP (▲)” “AGITATION (▼)”
and “PRODUCTION (◄►)” keys to enter
the password and then confirm it (fig.V/05).
If you do not know the password, contact
the Frigomat assistance service.
When the password has been accepted, the
screen accesses the list of programming
steps directly. The first programming step
P01 is selected automatically.
If you do not wish to change the value of the
selected step, press “STOP (▲)” to directly
access the following step (fig.V/06).
If, instead, you wish to change the selected
step, press “PRODUCTION (◄►)” to ac-
cess the parameters relative to the same
step, and subsequently press “STOP(▲)” or
“AGITATION (▼)” to increase or decrease
the value (fig.4). Subsequently, press the
“PRODUCTION (◄►)” key to confirm the
data (fig.V/07).
To quit the programming and save your changes, press the key "STOP (▲)"
to see a list of steps to the end. The exit from the programming is automati-
cally.
The list of parameters and related programming specifications is shown in
TAB V/01 at the end of this section.
V
PROGRAMMING
fig.V/01
fig.V/02
fig.V/03
fig.V/04
fig.V/05
fig.V/06
fig.V/07
for the technician