FAILURES IDENTIFICATION
4.1
Management of alarms
MESSAGE
DESCRIPTION
SOLUTION
EME
Cover open or unassembled.
Verify that the cover is assembled and in the closed position.
TER
A motor circuit breaker has intervened or the transformer fuse break-
down.
Wait a few minutes and then press STOP to restore machine opera-
tion. If the alarm continues, contact the technician
1
.
End
Batch freezing time
-
out alarm.
In the production cycle, select lower consistency levels. Make sure
that the product is balanced correctly. If the alarm continues, contact
the technician
1
.
TEv Int
TEv cor
The cylinder probe is interrupted or in short
-
circuit.
Contact the technician to check and replace the faulty probe.
TEc Int
TEc cor
The suction probe is interrupted or in short
-
circuit.
Contact the technician to check and replace the faulty probe
1
.
T
-
S
Reached the minimum temperature allowed on suction probe.
Make sure the freezing cylinder is not empty, that the mixture is pro-
perly balanced and that the selected program is suitable for the pro-
duct being processed. If the alarm persists, call the technician.1
PUR
Report the possible absence of power supply during the phases of
preserving mode
Check the reasons for the absence of power supply and the state of
of preservation of the product.
1
= These operations are reserved exclusively for authorised from the manifacturer and qualified personnel.The list of authorized technical assistance cen-
ters is available on the site: www.frigomat.com/en/partners/world.
The manufacturer declines all and any liability for damage caused by failure to comply with the above indications.