background image

14

920-159-02

Friedrich Air Conditioning Company 

P.O. Box 1540  

San Antonio, TX 78295 

210.357.4400 

www.friedrich.com

VERT-I-PAK

®

  A SERIES 

SINGLE PACKAGE VERTICAL AIR CONDITIONERS 

LIMITED WARRANTY 

SAVE THIS CERTIFICATE.  

It gives you specific rights, you may also have other rights which may vary from state to state and province to 

province. 

In the event that your unit needs servicing, contact your nearest authorized service center.  If you do not know the nearest service center, 
ask the company that installed your unit or contact us - see address and telephone number above.  To obtain service and/or warranty parts 
replacement, you must notify an authorized FRIEDRICH Air Conditioning Co. service center, distributor, dealer, or contractor of any defect 
within the applicable warranty period. 

When requesting service:

 please have the model and serial number from your unit readily available. 

Unless specified otherwise herein, 

the following applies:  

FRIEDRICH VERT-I-PAK A SERIES VERTICAL AIR CONDITIONERS AND HEAT PUMPS

LIMITED WARRANTY - FIRST YEAR (Twelve (12) months from the date of installation). 

Any part found to be defective in the material  

or workmanship will be repaired or replaced free of charge by our authorized service center during the normal working hours; and

LIMITED WARRANTY - SECOND THROUGH FIFTH YEAR (Sixty (60) months from the date of installation). ON THE SEALED 
REFRIGERATION SYSTEM.  

Any part of the sealed refrigeration system that is defective in material or workmanship will be repaired or 

replaced free of charge (excluding freight charges) by our authorized service center during normal working hours.  The sealed refrigeration 
system consists of the compressor, metering device, evaporator, condenser, reversing valve, check valve, and the interconnecting tubing. 

These warranties apply only while the unit remains at the original site and only to units installed inside the continental United
States, Alaska, Hawaii, Puerto Rico and Canada. The warranty applies only if the unit is installed and operated in accordance with 
the printed instructions and in compliance with applicable local installation and building codes and good trade practices. For 
international warranty information, contact the Friedrich Air Conditioning Company - International Division. 

Any defective part to be replaced must be made available to 

FRIEDRICH

 in exchange for the replacement part.  Reasonable proof must be 

presented to establish the date of install, otherwise the beginning date of this certificate will be considered to be our shipment date plus sixty 
days.  Replacement parts can be new or remanufactured.  Replacement parts and labor are only warranted for any unused portion of the 
unit’s warranty.

We will not be responsible for and the user will pay for: 

1. Service calls to:   

A) Instruct on unit operation.  B) Replace house fuses or correct house wiring.  C) Clean or replace air filters. D) Remove the unit 
from its installed location when not accessible for service required. E) Correct improper installations. 

2.  Parts or labor provided by anyone other than an authorized service center. 

3.  Damage caused by: 

A) Accident, abuse, negligence, misuse, riot, fire, flood, or acts of God.  B) Operating the unit where there is a corrosive atmosphere 
containing chlorine, fluorine, or any damaging chemicals (other than in a normal residential environment).  C) Unauthorized 
alteration or repair of the unit, which in turn affects its stability or performance.  D) Failing to provide proper maintenance and 
service.

E

) Using an incorrect power source. 

 F

) Faulty installation or application of the unit. 

We shall not be liable for any incidental, consequential, or special damages or expenses in connection with any use or failure of 
this unit.  We have not made and do not make any representation or warranty of fitness for a particular use or purpose and there
is no implied condition of fitness for a particular use or purpose.  We make no expressed warranties except as stated in this 
certificate.  No one is authorized to change this certificate or to create for us any other obligation or liability in connection with 
this unit.  Any implied warranties shall last for one year after the original purchase date.  

Some states and provinces do not allow 

limitations on how long an implied warranty or condition lasts, so the above limitations or exclusions may not apply to you.  The provisions of 
this warranty are in addition to and not a modification of or subtraction from the statutory warranties and other rights and remedies provided 
by law. 

In case of any questions regarding the provisions of this warranty, the English version will govern.  

(10-0

6

)

Summary of Contents for Vert-I-Pak VEA24 Series

Page 1: ...920 159 02 10 06 VERT I PAK A SERIES SINGLE PACKAGE VERTICAL AIR CONDITIONINGSYSTEM 24 000 BTU h INSTALLATION OPERATION GUIDE...

Page 2: ...Thermostat Control 12 10 Low Ambient Protection for Compressor Fan 12 11 Heating Defrost Heat Pump Models only 12 12 Fresh Air Door 13 13 Condensate Disposal System 13 IV Service Maintenance Warranty...

Page 3: ...a clearance of 24 from the outdoor louver should be maintained For major obstructions such as a solid fence wall or other heat rejecting device like a condensing unit a mini mum distance of 72 should...

Page 4: ...llar accepts 10 flex duct Section I General Specifications Vert I Pak Model Identification Guide ELECTRIC HEATER SIZE A Series 25 2 5 KW 34 3 4 KW 50 5 0 KW 75 7 5 KW MODEL NUMBER V E A 09 K 34 RT H E...

Page 5: ...p x 47 1 4 high VPAWP1 8 1 14 Wall Plenum cut out dimensions 24 5 8 wide x 30 7 8 high VPRG4 Access Panel cutout dimensions 27 wide by 55 3 4 high See Figure 8 Page 10 for proper chassis installation...

Page 6: ...side wall plenum Part A Inside Wall Plenum Part B Wall Plenum Outdoor Louver Installation Rough opening dimension 24 5 8 wide x 30 7 8 high Ensure that the bottom of the plenum is 1 1 2 from the floor...

Page 7: ...Sample Nameplate see your chassis nameplate MODEL VHA VEA24K25 VHA VEA24K34 VHA VEA24K50 VHA VEA24K75 Voltage V 230 208 230 208 230 208 230 208 LRA Comp A 68 68 68 68 Cooling Current A 13 7 12 4 13 7...

Page 8: ...branch circuit or general purpose outlet is grounded Wire Sizing Use recommended wire size given in tables and installasinglebranchcircuit Allwiringmustcomply with local and national codes NOTE Use co...

Page 9: ...2 5 KW 3 4 KW HEATER BLACK SEE NOTE 6 PRESSURE WHITE RELAY HEAT RELAY HEAT RELAY HEAT RELAY HEAT BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK RED RED RED RED RED RED RED RED 2 5KW 3 4KW 5 KW...

Page 10: ...ccessories for installation details Return Air Grille Options Figure 9 Field Supplied Return Air Grille Must have a minumum of 250 square inches of free area VPRG4 Return Air Grille with Access Panel...

Page 11: ...n to the condensate exit location Be sure to use teflon tape or approved pipe sealant on all drain connections and plugs see page 8 C Place the chassis into the closet with the outdoor side facing the...

Page 12: ...ticallyswitchestoelectricheatduring defrost Whentheoutdoorambienttemperaturedropsbelowa45 F factory setting the chassis automatically switches to electric heat As outdoor ambient temperatures rise abo...

Page 13: ...can be accomplished easily by referring to the following directions However before performing any maintenance consider these important safety precautions WARNING ElectricalShockHazard Beforeattemptin...

Page 14: ...e Friedrich Air Conditioning Company International Division Any defective part to be replaced must be made available to FRIEDRICH in exchange for the replacement part Reasonable proof must be presente...

Page 15: ...pecial color to match the exterior wall ARCHITECTURAL LOUVER Extruded aluminum louver that attaches to the outdoor section of the wall plenum DIMENSIONS 31 1 16 high x 25 9 16 wide Same as VPAWP1 8 bu...

Page 16: ...tory Certified Parts FRIEDRICH AIR CONDITIONING CO Post Office Box 1540 San Antonio Texas 78295 1540 4200 N Pan Am Expressway San Antonio Texas 78218 5212 210 357 4400 Fax 210 357 4480 www friedrich c...

Reviews: