Friedrich Digital Control Features Continued

Instant Heat 
Heat Pump Mode

Heat pump models will automatically run the electric heater to quickly bring the room up to temperature when initially en-
ergized, then return to heat pump mode. This ensures that the room is brought up to temperature quickly without the usual 
delay associated with heat pump units.

Even Heat 
Monitoring 

The digital control monitors indoor conditions to ensure that the room temperature is within 

fi

 ve degrees of the setpoint. If 

necessary the unit will cycle the electric heat to maintain the temperature. This feature ensures guest comfort by delivering 
the heating bene

fi

 ts of an electric heater while maintaining the ef

fi

 ciency bene

fi

 ts of a heat pump.

Fan Cycle Control

The owner may choose between fan cycling or fan continuous mode based on property preference. (Note: Even heat 
monitoring and quiet start/stop fan delay only operate in fan cycle mode) Fan continuous mode is used to keep constant 
air

fl

 ow circulation in the room during all times the unit is ‘ON’. Fan cycle will conserve energy by only operating the fan while 

the compressor or electric heater is operating.

Emergency Heat 
Override

In the event of a compressor failure in heat pump mode the compressor may be locked out to provide heat through the 
resistance heater. This feature ensures that even in the unlikely event of a compressor failure the room temperature can 
be maintained until the compressor can be serviced.

Desk Control 
Ready

All Friedrich digital PTACs have low voltage terminals ready to connect a desk control energy management system. Con-
trolling the unit from a remote location like the front desk can reduce energy usage and requires no additional accessories 
at the PTAC.

Indoor Coil Frost 
Sensor

The frost sensor protects the compressor from damage in the event that air

fl

 ow is reduced or low outdoor temperatures 

cause the indoor coil to freeze. When the indoor coil reaches 30

°

F the compressor is diabled and the fan continues to 

operate based on demand. Once the coil temperature returns to 45

°

F the compressor returns to operation.

Ultra-Quiet Air 
System

The new Friedrich PD series units feature a indoor fan system design that reduces sound levels without lowering air

fl

 ow 

and preventing proper air circulation.

High Ef

fi

 ciency

The Friedrich PTAC bene

fi

 ts from quality components and extensive development to ensure a quiet, ef

fi

 cient and depend-

able unit.

Single Motor 

Friedrich’s single-motor design allows for enhanced outdoor air

fl

 ow and simpli

fi

 es the unit design without the need for 

redundant components.

Rotary Compressor

High ef

fi

 ciency rotary compressors are used on all Friedrich PTACs to maximize durability and ef

fi

 ciency.

Auxiliary Fan Ready

The Friedrich PTAC features a 24V AC terminal for connection to an auxiliary fan that may be used to transfer air to adjoin-
ing rooms. Auxiliary fans can provide conditioning to multiple rooms without the requirement of multiple PTAC units.

Aluminum 
Endplates

All Friedrich PTACs are built with .04" endplates made from aluminum as opposed to steel. The endplates are typically the 
most susceptible area for corrosion and aluminum is far more resistant to corrosion than even coated steel.

Diamnonblue 
Technology

Diamonblue (seacoast protection) protects the outdoor coil from harsh environments. Comes standard on all PTAC units.

Top Mounted Anti-
microbial Air Filters

All Friedrich PTAC return air 

fi

 lters feature an anti-microbial element that has proven to prevent mold and bacterial growth 

in laboratory testing. PDXFT replacement 

fi

 lter kits feature the same anti-microbial agent. All 

fi

 lters are washable and reus-

able and are easily accessed from the top of the unit without the removal of the front cover.

Filtered Fresh Air 
Intake

Friedrich PTAC units are capable of introducing up to 70 CFM of outside air into the conditioned space. The outdoor air 
passes through a mesh screen to prevent debris from entering the airstream.

Summary of Contents for PDH07K3SB1

Page 1: ...920 087 06 4 08 PTAC PACKAGED TERMINAL AIR CONDITIONERS HEAT PUMPS Standard Control Remote Thermostat Seacoast Protected INSTALLATION OPERATION GUIDE...

Page 2: ...trol Diagnostics and Test Mode 26 Accessories 27 28 Warranty 29 Table of Contents Your safety and the safety of others are very important CAUTION NOTICE We have provided many important safety messages...

Page 3: ...3 920 087 06 Typical Unit Components Front cover Chassis Wall sleeve Outdoor grille...

Page 4: ...and install the equipment Installation must be in conformance with the NFPA 70 2008 National Electric Code or current edition and Uniform Mechanical Code current edition and applicable local or natio...

Page 5: ...AC units should be installed no closer than 12 apart when two units are side by side If three or more PTAC units are to operate next to one another allow a minimum of 36 between units Also a vertical...

Page 6: ...new Friedrich digital PTAC features a self diagnostic program that can alert maintenance to component failures or operating problems The internal diagnostic program saves properties valuable time whe...

Page 7: ...cause the indoor coil to freeze When the indoor coil reaches 30 F the compressor is diabled and the fan continues to operate based on demand Once the coil temperature returns to 45 F the compressor re...

Page 8: ...locally to connect the internal drain tube to the drain system in the building 6 Referring to Detail A on page 9 locate and assemble the 2 two cover plates and gaskets over the drain holes at the rear...

Page 9: ...ard the wall sleeve 3 Attach the drain tube assembly to one of the two drain holes at the rear of the wall sleeve The large flange on the mounting plate is positioned at the bottom of the sleeve facin...

Page 10: ...e higher than the back Electrical shock hazard Turn electric power OFF at the fuse box or service panel before making any electrical connections and ensure a proper ground connection is made before co...

Page 11: ...re not followed Figure7 NOTE Construct wall opening to comply with all applicable building codes Main studs Jack studs Main studs Jack studs Lintel Mounting screw holes No holes in bottom of wall slee...

Page 12: ...Secure the wall sleeve extension to the wall sleeve before installing it in the wall Refer to Figure 8 for a guide for fabrication ofacondensatedrippanel ThepanelMUSTextendthefulldepth of the wall sl...

Page 13: ...outs facing down From inside the building maneuver the grille through the wall sleeve and pull toward you until the screw heads are inserted into the keyhole slots at the top of the wall sleeve Tighte...

Page 14: ...eets the UL and NEC requirements for cord connected air conditioners effective August 2004 To test your power supply cord 1 Plug power supply cord into a grounded 3 prong outlet 2 Press RESET 3 Press...

Page 15: ...ressor Chassis shipping bracket Shipping pallet IMPORTANT WheninstallingaFriedrichP SeriesPTACintoan existing sleeve it is important to ensure that the unit is installed completely Inspection of the a...

Page 16: ...g brackets on the wall sleeve flange two per side 6 Install the front cover assembly including the discharge grille by placing the top of the cover onto the 90 angle bracket along the top of the chass...

Page 17: ...onditions and in the event that the room falls below 40 F the unit will cycle on high fan with the electric heater This occurs regardless of mode 4 Emergency Heat Override Switch 7 In the unlikely eve...

Page 18: ...mergencyHeatOperation In the event of a compressor failure in heat pump mode the com pressormaybelockedouttoprovideheatthroughtheresistance heater This feature ensures that even in the unlikely event...

Page 19: ...ommand to the PTAC unit The remote signal has some ability to bounce off of walls and furniture similar to a television remote control The diagram below shows the typical operating range of the contro...

Page 20: ...To revert back to the Smart Center control of the unit replace the jumper wire between the GL and GH terminals that was removed in step 1 ThermostatConnections C Common Ground W Call for Heating Y Cal...

Page 21: ...r tampering with the unit s internal wiring can void the equipmentwarrantyandmayresultinpropertydamage personal injury or death Other manufacturer s PTACs and even older Friedrich models may have diff...

Page 22: ...ure components and accessories such as the control door and front cover Check the unit air filter condenser coil and evaporator coil for any obstructions Check for proper operation of all components I...

Page 23: ...maintenance and service to the chassis Line Voltage Connections Figure18 5 Make the appropriate electrical connections within the control box then secure the box on the chassis Detailed instructions a...

Page 24: ...coil cleaning agent on coils or base pan Use a biodegradable cleaning agent and degreaser NOTE Units are to be inspected and serviced by qualified service personnel only Discharge Air Grille Filters...

Page 25: ...for proper sizing Istheoutdoortemperature60 Forbelow The unit is designed for outdoor temperatures above 60 F Istheindoortemperature80 Forabove Ambient indoor temperatures of 80 F or above will take...

Page 26: ...rror code Leave unit running Defective sensor 05 Outdoor coil thermistor sensor open Or short circuit Set OD coil temp 20 F Alternately flash set point and error code Automatically change over to Elec...

Page 27: ...to the outside of the wall sleeve when the wall is greater than 11 inches thick 9 when a subbase is used 10 inches when a lateral duct is used Up to three exten sions my be used together PXSB DECORAT...

Page 28: ...r The extension can be cut to length by the installer Maximum allowable straight extension is 15 feet PXCJ CONDUIT KIT WITH JUNCTION BOX Hard wire conduit kit with junction box for 208 230V and 265V u...

Page 29: ...sented to establish the original purchase date otherwise the beginning date of this certificate will be considered to be our shipment date plus sixty days Replacement parts can be new or remanufacture...

Reviews: