![FRIATEC FRIAMAT Operating Instructions Manual Download Page 6](http://html1.mh-extra.com/html/friatec/friamat/friamat_operating-instructions-manual_2332085006.webp)
6
1.4
Sources of Danger
- Damaged connection leads and extension cables must be replaced
immediately
- Do not either remove safety devices or put them out of action
- Eliminate known faults immediately
- Do not leave your FRIAMAT
®
model unattended
- Keep away from flammable liquids / gases
- Do not operate in an Ex-environment
1.5
Permitted users
Only trained personnel may work with your FRIAMAT
®
model. The operator is
responsible for third parties in the working area The user must:
- make the operating instruction available to the operator and
- satisfy himself that the latter has read and understood them
1.6
Dangers from electrical power
- Do not use any damaged connecting cables
- Check the connection leads for damage
- Pull out the power supply plug before all care and maintenance work !
- Only have servicing, maintenance and repairs carried out by authorised
service centres
- Only connect the fusion units of the FRIAMAT
®
Family to the supply
voltage stated on the rating plate
WARNING !
Distribution points on the construction site: Comply with
the regulations on circuit breakers
Outdoors (on construction sites) sockets must be fitted with earth leakage
circuit breakers. If using generators the DVGW Work Sheet GW 308 and
VDE 0100 Part 728 must be complied with. The generator output rating
required is dependent on the power requirements for the largest fitting being
used, on connection conditions, ambient conditions and the actual generator
type (its control characteristics). Since generators from different model ranges
exhibit very different control characteristics the suitability of a generator
cannot always be guaranteed by the specified rated output alone.