![FRIATEC FRIAMAT Operating Instructions Manual Download Page 10](http://html1.mh-extra.com/html/friatec/friamat/friamat_operating-instructions-manual_2332085010.webp)
10
2.2
Transport / storage / despatch
Your FRIAMAT
®
model is delivered in a transport box. There are no particular
requirements for unpacking, or for (temporary) storage in the transport box.
Storage temperature - 20
°
C to + 70
°
C
WARNING !
Do not damage the front face of your FRIAMAT
®
model !
Always despatch in the transport box.
2.3
Setting up / connection
If protected from rain and wet your FRIAMAT
®
model can be set up and
operated out of doors.
- Set up the FRIAMAT
®
on level ground (as near horizontal as possible).
- Ensure that generator is fused with a 16 A minimum (slow acting) fuse.
- Plug the mains plug into the mains socket or connect to the generator.
- If necessary use an extension cable, ensuring that the cross section is
adequate (see section 2.1 “Technical Data”).
- Always comply with the operating instructions for the generator.
WARNING !
Always unroll the cable before use
2.4
Putting into service
WARNING !
Charring ! Dirty contacts can char the plug.
The contact surfaces of the fitting and the fusion plug must always be clean.
- Remove any existing deposits thoroughly
- Protect the plug from contamination, replacing it if necessary
- Check the fusion plugs and contact sockets on the fitting for dirt, and only
then make the connection