6.3
Checking the reader wand
If the reading is not confirmed after reading in a bar code several times
the reader wand can be checked by reading in the TEST code (see plastic
card in the accessories pouch). “TEST CODE” will appear in the display for
4 seconds.
6.4
Taking out of service
IMPORTANT ! The fusion units of the FRIAMAT
®
Family contain various
components which make it necessary to ensure that it is
disposed of properly. Your FRIAMAT
®
model can be
disposed of at the factory or at one of the Authorised
Service Centres
7.
Operating faults
7.1
Faults when reading in the bar code
If the reading in is not confirmed by an acoustic signal the reader wand
should be checked for dirt or physical damage. If the reader wand is
defective there is still the facility to carry out the fusion using the Emergency
Input Mode (see below).
7.2
Emergency Input
Go into the “Emergency Input” setting menu via the Main Menu. “Emergency
Input” will appear in the top line of the display, whilst in the bottom line you
will see “Yes” on the left, “Continue” in the centre and “End” on the right.
When the START button is pressed “Code” and 24 characters will appear,
with the first character flashing. This can be increased by pressing the INFO
button or decreased by pressing the MENU button. With the START / STOP
button you can move left or right within the Emergency Input menu. The
figures to be entered should be read off the bar code of the fitting being
fused. After entering the numbers for the bar code you have to confirm the
entry by pressing the SET button - by pressing the RES button you can break
off the process. The fusion process is started by pressing the START button.
Code:
36 18 09 01 06
38 35 08 99 05 47 00