background image

Operating Instructions

FRIAMAT

®

FRIAMAT

®

FM_2427_2_GB_03_12.qxp:-  28.03.2012  9:28 Uhr  Seite 1

Summary of Contents for FRIAMAT GEO PRINT

Page 1: ...Operating Instructions FRIAMAT FRIAMAT...

Page 2: ...2 2 Operating principle 9 2 3 Technical data 10 2 4 Automatic activation of Service interval 11 2 5 Transport Storage Despatch 11 2 6 Setting up Connecting 11 2 7 Operating 12 3 Basic Fusion Procedure...

Page 3: ...t of service 19 6 Operating faults 20 6 1 Errors when reading in the barcode 20 6 2 Overheating 20 6 3 Fusion interruption 20 6 4 Error messages Warning messages Info 20 7 Appendix 23 7 1 Recommended...

Page 4: ...with regard to the health of the user your FRIAMAT fusion unit or other material goods of the operator the efficient operation of your FRIAMAT fusion unit Everybody involved with operating servicing...

Page 5: ...83 and to ISO 13950 03 2007 The designated use also includes observation of all the advice in these operating instructions as well as the guidelines by DVGW Standards DVS UVV and local directives IMPO...

Page 6: ...ior to any maintenance or service tasks Allow any service and repairs to be carried out only at authorised service stations Connect fusion units of the FRIAMAT range only to supply voltage as given on...

Page 7: ...ess Your FRIAMAT fusion unit has been designed for input voltage of 190 250 volt When using an extension cable please ensure suffi cient cross section 2 5 mm2 up to 100 m Always roll out cable fully b...

Page 8: ...rmed 2 signals fusion process completed 3 signals supply voltage too low too high 5 signals warning error refer to display 1 10 Emergencies In case of an emergency switch off main switch immediately t...

Page 9: ...ble conti nuously measures the ambient temperature WARNING The temperature sensor for determining the ambient temperature is attached to the fusion cable at the reader wand cable near the reader wand...

Page 10: ...uit and Cut Off Printer interface USB Connecting plug 4 0 mm yes Manual emergency yes programming Remote operating pass optional Operator pass no Supervisor pass no FRIATRACE no Documentation of fusio...

Page 11: ...packing requires no specific skills nor does storage in the transport box The tempe rature range during storage is 20 C 70 C WARNING Always transport store inside aluminium trans port box 2 6 Setting...

Page 12: ...be observed The same applies for fittings by other manufacturers IMPORTANT Roll out cables completely This applies to power cable fusion cable and extension cable if required The contact surfaces of t...

Page 13: ...e fitting as a resistance check is carried out imme diately after reading in the barcode An error message will appear if there is non contact Please also ensure that the fusion plugs of your FRIAMAT f...

Page 14: ...anufacturer please observe operating instructions by the appro priate fitting manufacturer Operating steps see also the visual description on the next page 1 Display shows PIPE PREPARED confirm if cor...

Page 15: ...STOP The STOP button is red It cancels the fusion process is used to close submenus or indivi dual menus and stops the entering process without saving data Arrow buttons The arrow buttons are blue Th...

Page 16: ...documentation is switched on and an initial set of data has been saved 4 3 1 Menu Transfer The guide button MENUE will take you to the menu Data with its submenu Transfer Your FRIAMAT geo print will...

Page 17: ...nce you have deleted data it has been lost irrevocably The unit has an automatic back up function which may allow authorised FRIATEC service personnel to retrieve deleted data Please contact your loca...

Page 18: ...bers have been entered using the arrow buttons you must confirm this by pressing the START button if you press the STOP button the process will be stopped without saving data 4 6 Menu Formatting Press...

Page 19: ...ld be carried out once a year see list of authorised service points in section 7 2 Please include all connecting adapters for service checks WHAT WHEN WHO Cleaning the reader daily user wand and check...

Page 20: ...nit cool down As the power consumption of different electrofusion fittings will vary there may be the option of fusing a different fitting 6 3 Fusion interruption If the fusion is interrupted because...

Page 21: ...checks fitting 05 Fitting Current flow Check winding interrupted connection open circuit of fusion plug on fitting If okay replace the fitting and send in for checks 06 Voltage Non Contact outside per...

Page 22: ...r Please contact failure maybe not FRIATEC suited for service hotline fusion work 49 0 621 486 1533 xy System Please contact error FRIATEC service hotline 49 0 621 486 1533 error messages with numbers...

Page 23: ...vice date exceeded point Arrange for unit to be serviced 7 Appendix 7 1 Recommended accessories FRIATEC Memory Stick USB to transfer fusion data from fusion unit to PC Laptop option Remote control pas...

Page 24: ...2427 2e 13 03 2012 FRIATEC Aktiengesellschaft Technical Plastics Division P O Box 71 02 61 D 68222 Mannheim Phone 49 621 486 1533 Fax 49 621 479196 www friatools com info friatools friatec de...

Reviews: