Error messages:
No Text in
Significance/ Remedy
Display
Causes
02 Temperature Ambient
Set up tent if
outside temperature
necessary.
range
outside
permitted
range.
03 Resistance Electrical
Check
contact
outside
resistance of
for firm
tolerance
fitting outside seating/dirt.
tolerance. Maybe
clean
contacts,
if necessary
replace fitting.
04 Fitting
Short circuit
Replace fitting,
winding
in the wire
send in for
short circuit winding of
checks.
fitting.
05 Fitting Current
flow
Check
winding interrupted.
connection
open circuit
of fusion
plug on fitting.
If okay replace
the fitting and
send in for
checks.
06 Voltage Non-
Contact
outside permitted
de- authorised
tolerance
viation of fu-
service point.
sion voltage.
08 Mains Power Extension
cable
voltage voltage
too long or cross
outside
outside
section too small.
range
permitted Check
voltage
range during and connections
fusion. of
generator.
09 Frequency Frequency Check
outside
outside frequency
of
range
permitted generator
range during voltage.
fusion.
10 Cancel of
Fusion inter-
–
fusion rupted
by
pressing the
STOP button.