8
1.7
Emissions
The (equivalent) continuous sound pressure level of
all FRIAMAT
®
fusion units is less than 70 db(A).
When working in a quiet environment, the signal
when set to “loud” comes across as very loud. For
this reason it is possible to adjust the signal
(loud/quiet).
1.8
Safety precautions on site
WARNING!
FRIAMAT
®
fusion units are splash water proofed.
They may however not be immersed in water.
1.9
Signal equipment
FRIAMAT
®
fusion units confirm certain operating
procedures using a signal (1, 2, 3 or 5 signal
sounds). The signals signify the following:
1 signal:
reading in of barcode confirmed.
2 signals: fusion process completed.
3 signals: supply voltage too low/too high.
5 signals: warning: error, refer to display!
1.10
Emergencies
In case of an emergency switch off main switch
immediately to the “OFF” position and disconnect
your FRIAMAT
®
fusion unit from the power supply.
FRIAMAT
®
fusion units can be shut off by:
- Activation of main switch or
- Pulling out the power supply plug.
2
Basic settings
2.1
Design/Parts
All electronic parts of your FRIAMAT
®
fusion unit are
kept in a splash water proofed casing. A receptacle
for the fusion and mains cable is situated at the
back. At the top there is an accessory box; at the
right side is the interface box. FRIAMAT
®
fusion units
are designed for a maximum fusion voltage of 48 V.
A safety transformer separates supply and fusion
voltage.
FM_2427_2_GB_03_12.qxp:- 28.03.2012 9:28 Uhr Seite 8