4
3.
Standard publications and specifications for use
For detailed and up-to-date information on FRIALEN
®
Safety Fittings, please
see the technical datasheets available on the Internet (www.frialen.com).
Please observe the guidelines of the DVGW standard publications, and of the
DVS, BGR 500 (VBG 50), EN 1555, EN 12201, EN 13244, UVV and
respectively national regulations.
DANGER!
The described sequence of the processes is absolutely to be adhered to.
FRIALEN
®
Safety Fittings
can be used with pipes made of
PE 100,
PE 80, PE 63, PE 50
according to DIN 8074/75, EN 1555-2, EN 12201-2,
EN 13244-2, ISO 4437 and ISO 4427.
For PE pipes, a fusion flow rate MFR 190/5 in the range of 0.2 – 1.7g/10 min.
applies.
We recommend using pipes with a limited dimension tolerance range,
tolerance class B.
FRIALEN
®
Safety Fittings
consist of PE 100 and meet the requirements
according to DIN 16963-5, -7, EN 1555-3, EN 12201-3, EN 13244-3,
ISO 8085-3 as well as the DVGW test bases. FRIALEN
®
Safety Fittings can
be fused with FRIAMAT
®
Electrofusion Units at ambient temperatures
between - 10
°
C and + 45
°
C. Fittings from d 710 between 0
°
C and + 45
°
C.
For material transition joints, the material- or system-specific standards and
installation guidelines apply in addition.
WARNING!
Fusion with other pipe materials such as e.g. PP, PVC etc. is not
possible.
WARNING!
Pipes and moulded components should have settled to a balanced
temperature level between - 10
°
C and + 45
°
C (Couplers UB d 710 between
0
°
C and + 45
°
C) when being processed.
FL_2104_8_GB_II_08.p65
25.03.2008, 9:48 Uhr
4
Summary of Contents for FRIALEN
Page 31: ...31 ...