13
WARNING!
Between preheating and fusion, a waiting time is always required to
ensure heating through of the component parts. This waiting time
corresponds approximately to the preheating or fusion time, depending
on the dimension approx. 15-30 minutes. If only one coupler side is to
be processed, the waiting time between preheating and fusion is to be
observed.
If the waiting time is exceeded by more than the double time, the
described process is to be repeated.
4.9
Carrying out the fusion
WARNING!
Only use fusion units which have
been approved by the manufac-
turer with regard to their function
for the processing of FRIALEN
®
Safety Fittings. See DVS 2207-1.
Use FRIAMAT
®
fusion units only
for FRIALEN
®
UB d 710!
For the fusion of the coupler d 800
please observe our FRIALEN
®
Info
No. 42.
The fusion parameters are contained in the main barcode affixed to the
FRIALEN
®
Safety Fitting
. When using fully automatic fusion units (e.g.
FRIAMAT
®
), the parameters are entered into the fusion unit using the reader.
After reading of the barcode (see Figure 9a), the fitting data are to be
compared with the data shown on the unit’s display.
The subordinated barcode contains the data for component traceability (see
information). This barcode is only to be read if the component traceability
function is to be used. This requires suitable fusion units.
The fusable pipe series are listed in the SDR labelling on the label.
The fusion units automatically monitor the fusion process and control the
supplied energy in determined limits.
Figure 9a