P33
FIZ (FOCUS, IRIS, ZOOM) MAIN SCREEN WITH PERCENTAGE SCALES
SCREEN WITH 3 AXIS LENS MAPPING ACTIVE
MENU STRUCTURE
The Wedge is controlled and configured by several dedicated MoVI Controller Screens described below. Primary navigation and control is achieved by scrolling and
pressing the MENU and SET buttons.
FIZ MAIN
This is the typical “Home” screen for FIZ multi-axis operations. It shows the positions of all axes and provides access to the majority of common control commands.
• Positions of Each Axis:
Displayed in Percent or, when a Lens Map is selected, physical units. Units are changeable on the FIZ Config. Screen.
• Z-Spd:
Zoom speed scaling.
• CAM (Camera Status)
: STBY/REC. This is the status of the output for simple output type run stop camera interfaces, (RED EPIC, RED ONE, ARRI RS) or status from
the camera for serial interfaces (LANC, Sony MT, etc).
• Limits:
Allows setup of motor range limiting. Move the motor to the position you would like the first limit to be set. Highlight the limits field. Press the SET button
and keep it pressed. Move the knob to the second limit. Release the SET button. The entire range of the control knob will now cause motor motion in the limited
range. Momentarily press and release the button again to turn off the limits.Z-Spd: (Zoom Speed) Zoom Speed Scaling.
• Lock:
With this field selected, pressing the SET button locks the position so that knob movement doesn't move the motor. Press the SET button again to unlock.
• CAL:
With this field selected, pressing the SET button requests an auto calibration to be performed on each axis.
• RESET:
Clears Faults on any faulted axes. Axis reset to the un-calibrated state.
• Lens: The focal length of the currently selected lens.