P21
• SYSTEM OPTIONS
SAVE SETTINGS
Save M
ō
VI configuration to non-volatile (long-term) memory from here. Settings changes not saved before powering down or rebooting
the M
ō
VI will be lost.
REBOOT MōVI
Reinitialize the M
ō
VI. This can be useful for clearing any Errors that occur during M
ō
VI start-up.
• TILT/ROLL/PAN
STIFFNESS
• AUTO TUNE
• AUTO TUNE
SET (%):
• GYRO/OUTPUT
FILTER
These settings control how much the motors are used to stabilize the camera on each axis. For best performance, each Stiffness value
should be as high as possible without causing oscillation on its axis. Generally, heavier cameras allow for higher Stiffness settings. Reverse
the direction of the Focus Knob input.
The MōVI is capable of automatically adjusting Stiffness settings once a camera payload has been attached
and balanced. Select “Start” to begin the process.
The Auto Tune process adjusts the Stiffness settings until oscillation is detected, then sets the final values to a fraction of the value at
the onset of oscillation. This parameter adjusts the safety margin used. 50% is a good value for most applications (50% --MōVI M10 and
70% --MōVI M5) . A higher value may result in better performance. A lower value allows for more flexibility in adjusting focal length, changing
lenses, or adding accessories without retuning.
(Expert Settings) These settings adjust the strength of the filters applied to the MōVI’s gyro inputs and motor outputs, respectively. If
the MōVI is experiencing oscillations that cannot be corrected by adjusting Stiffness settings, you can use the filters to further tune the
gimbal and remove oscillations. As a general rule, if the oscillations are fast and rough in nature (buzzing/vibration), try increasing the filter
values. If the oscillations are slow and smooth in nature (rocking), try decreasing the filter values. The following factory-default values work
well in most cases:
GYRO FILTER
OUTPUT FILTER
MōVI M5
3
3
MōVI M10
5
5
MōVI CONFIG