background image

21

Use the correct media

Data cartridges

Ultrium tape drives use Ultrium tape cartridges. These are single-reel cartridges that match 

your drive's format and are optimized for high capacity, throughput and reliability. 

Compatible media can be recognized by the Ultrium logo, which is the same as the logo on 

the front of your drive. Do not use other format cartridges in your tape drive and do not use 

Ultrium cartridges in other format tape drives.

Write-protecting cartridges

If you want to protect the data on a cartridge from being altered or overwritten, you can write-

protect the cartridge. 
Always remove the cartridge from the tape drive before you change the write protection.
• To write-protect a cartridge, slide the red tab by the label area on the rear face of the 

cartridge to close the hole. Note the padlock on the tab that indicates that the cartridge is 

protected. 

• To write-enable a cartridge, slide the red tab back so that the hole is open before loading 

it into the drive. Figure 8 illustrates the location of the write-protect tab.

Write-protection will not prevent a cartridge being erased by bulk-erasure or degaussing. 

Do 

not bulk erase Ultrium format cartridges.

 This will destroy pre-recorded servo information and 

make the cartridge unusable.

Cleaning cartridges

You must use Ultrium cleaning cartridges with Ultrium tape drives, as other cleaning cartridges 

will not load and run. We recommend the Ultrium Universal cartridge. Unlike some earlier 

Generation 1 Ultrium cleaning cartridges, the orange colored Ultrium Universal cleaning 

cartridge is designed to work with any Ultrium compliant drive. Do not use other format 

cartridges in your tape drive and do not use Ultrium cartridges in other format tape drives.

To clean the tape drive:

A cleaning cartridge is supplied with each tape drive and should only be used when the 

orange Clean LED is flashing. 

1

Insert the cleaning cartridge.

2

The drive will carry out its cleaning cycle and eject the cartridge on completion (which can take 

up to 5 minutes). During the cleaning cycle the orange Clean LED will be on solidly and the 

green Ready LED will flash. 
Each cleaning cartridge can be used up to 15 times. If the cleaning cartridge is ejected 

immediately with the Tape Error LED on, it has expired. 

gen2 external oem.fm  Page 21  Thursday, February 13, 2003  3:02 PM

Summary of Contents for Ultrium Generation 2

Page 1: ...8OWULXP HQHUDWLRQ WHUQDO 7DSH ULYHV HWWLQJ 6WDUWHG XLGH...

Page 2: ......

Page 3: ...efore you start page 3 Backup software and drivers page 5 Usage models page 7 Installing the tape drive Step 1 Check the SCSI connection page 9 Step 2 Check the drive s SCSI ID page 11 Step 3 Connect...

Page 4: ...h the furnishing performance or use of this material whether based on warranty contract or other legal theory Linear Tape Open LTO LTO Logo Ultrium and Ultrium Logo are U S trademarks of HP IBM and Se...

Page 5: ...is supplied with a 68 pin wide VHD to HD SCSI cable to attach to the host server or fibre channel bridge Fibre channel connection If you are using your tape drive on a fibre channel FC network you wil...

Page 6: ...s and all necessary cables and mounting hardware are provided in this kit If you do not have a VHD wide SCSI connector on your server or bridge you will need to purchase and install a VHD to HD adapte...

Page 7: ...plication that supports Ultriumtape drives and download any upgrades or patches if required Drivers Windows users Before you install the tape drive download the driver from the manufacturer s web site...

Page 8: ...6 Figure 1 usage models Direct attach SCSI Direct attach FC SCSI Network attach SCSI Network attach FC SCSI Storage Area Network SAN tape drive FC SCSI bridge server...

Page 9: ...tach LAN The tape drive is directly attached to a network storage server that can be accessed by a number of clients or workstations As with the direct attach model the connection is via a SCSI link o...

Page 10: ...8 Figure 2 checking the SCSI connection connecting to a FC SCSI bridge connecting to an HBA card in the server...

Page 11: ...the only device on the bus This is the recommended configuration Do not connect to a RAID controller channel This is for disk drives only 3 Is the spare port on an Ultra 3 160 or Ultra 4 320 SCSI bus...

Page 12: ...10 3 Figure 3 checking the SCSI ID...

Page 13: ...because small bits of lead could contaminate the drive Note The computer and the tape drive SCSI IDs are only checked at power on To change the SCSI ID after installation power down both the computer...

Page 14: ...12 Figure 4 connecting the SCSI cable SCSI IN Connector SCSI OUT Connector...

Page 15: ...ocumentation for information about connecting the bridge to the fibre channel adapter on the server or to the SAN fabric 4 Attach the HD connection on the SCSI cable to the SCSI IN connector on the re...

Page 16: ...14 Figure 5 connecting the power cable...

Page 17: ...trium tape drive will operate using any voltage in the range 100 240 volts 50 60 Hz No adjustment is needed 1 Plug the power cable securely into the socket on the rear panel of the drive 2 Plug the ot...

Page 18: ...16 Figure 6a loading a cartridge Figure 6b unloading a cartridge arrow indicates leading direction affix label here eject button power on off button...

Page 19: ...to check that the drive can write data to tape Use the blank cartridge supplied with the tape drive See Use the correct media on page 21 for more information about recommended cartridges To load a ca...

Page 20: ...18 Ready Drive Error Tape Error Clean Eject button Act TERM Fan PWR Fault Figure 7b rear panel indicators Power On Off button Emergency Reset Figure 7a tape drive controls and indicators...

Page 21: ...drive mechanisn has detected a hardware error Tape Error third amber Off no fault has been detected Flashing the tape currently in the drive is faulty This LED could come on for a number of reasons b...

Page 22: ...20 Figure 8 write protecting cartridges padlock indicates cartridge is protected...

Page 23: ...protect tab Write protection will not prevent a cartridge being erased by bulk erasure or degaussing Do not bulk erase Ultrium format cartridges This will destroy pre recorded servo information and ma...

Page 24: ...r humid conditions Do not leave cartridges in direct sunlight or in places where magnetic fields are present for example under telephones next to monitors or near transformers Do not drop cartridges o...

Page 25: ...drive will not be able to deliver 60 MB s transfer rates Some file systems are able to transfer data faster than others The type of data being backed up can affect backup performance for example file...

Page 26: ...e correct speed You may need to tune the transfer buffer and block size settings to optimize the speed that the application writes data to the tape drive Ultrium 460 tape drives have an internal buffe...

Page 27: ...lf If the device is displayed during boot up but cannot be found in the operating system this is more likely to be a software problem If you encounter a problem during installation and need further cl...

Page 28: ...umber is already in use Full instructions on how to change the SCSI ID are given on page 11 Description Further information It is unclear if the bus is already terminated or where an additional termin...

Page 29: ...SCSI bus has a unique ID We recommend that the Ultrium tape drive is connected to a dedicated host bus adapter Do not connect the drive to a disk RAID controller as this is not supported You have inst...

Page 30: ...ommended action If the drive does not power up all LEDs are off the power cable may not be connected to the drive properly The power on off switch incorporates a green LED If this is not on check the...

Page 31: ...oubleshooting Use the following table to interpret the front panel LED sequences and the appropriate action to take if any LED Sequence Cause Action required All LEDs OFF Drive may not have power may...

Page 32: ...ctions If the clean LED is still flashing when you load a new or known data cartridge after cleaning call for service Ready is FLASHING and Clean is ON Cleaning is in progress None The cleaning cartri...

Page 33: ...and Ready FLASHING There is a firmware download problem Insert a cartridge to clear the LED sequence If the condition persists call for service Drive Error and Ready ON with Tape Error and Clean OFF S...

Page 34: ...e It is important that you allow sufficient time for the drive to complete this process If you interrupt it you may damage the media or the tape drive 3 If the cartridge is still jammed press the emer...

Page 35: ...own good piece of media and see if it loads If it does the original cartridge is faulty and should be discarded 6 Check if another Ultrium 460 drive will accept the cartridge If it does the original d...

Page 36: ...34...