6.Command Specification
REQUEST SENSE
SONY AIT-1 Turbo drive SDX-450V series Ver.1.0
6-90
0Dh
VOLUME OVERFLOW
00 02
END-OF-PARTITION/MEDIUM DETECTED - During Write type operation.
0Eh
MISCOMPARE. Not supported by the SDX-450V
0Fh
RESERVED. Not used by SDX-450V
REQUEST SENSE returns the CHECK CONDITION status only to report fatal errors for the REQUEST SENSE
command.
For example:
The target receives a non ZERO reserved bit in the command descriptor block.
An un-recovered parity error occurs on the Data Bus.
A target malfunction prevents return of the sense data.
The Allocation Length falls between block boundaries.
Following a fatal error on REQUEST SENSE, the sense data should be considered invalid. The host may attempt
recovery by selecting the drive and issuing a BUS DEVICE RESET message directly following the IDENTIFY
message. This forces the drive to do a hard reset. If the fault persists, the host should deny access to the drive.