13.Appendix F
SONY AIT-1 Turbo drive SDX-450V series Ver.1.0
13-6
LOG SENSE Command ( 4Dh )
Bit
Byte
7 6 5 4 3 2 1 0
0
Operation Code (4Dh)
1
Logical Unit Number
Reserved
PPC (0)
SP (0)
2
PC
Page Code (3Eh)
3
(MSB)
4
5
6
Parameter Pointer
(LSB)
7
(MSB) Allocation
Length
8
(LSB)
9
Unused (00b)
Reserved
Flag
Link
Bit
Byte
7 6 5 4 3 2 1 0
0
Page Code (3Eh)
1
Reserved
2
(MSB)
3
Page Length
(LSB)
4
(MSB)
5
Parameter Code
(LSB)
6
DU DS TSD ET
TMC
Reserved
LP
7
Reserved
8
(MSB)
User Data Length
9
(n-10)
10
:
:
User Data
n
13.8.3.
How to Update the User Volume Note
The data update operation for MIC is accomplished by overwriting the current data with new data, and this means
that you have to rewrite the entire User Volume Note even if you want to change only a part of it. Always check
whether the UVN exists by interrogating the drive about the size of the UVN: you will get 0 byte size if there is no
UVN.
SDX-450V reports an error condition (illegal parameter list length) if the User Volume Note Data Size is ZERO.