![background image](http://html1.mh-extra.com/html/freecom/fc-tapeware-ait-450i/fc-tapeware-ait-450i_manual_2329528073.webp)
LOG SENSE
6.Command Specification
SONY AIT-1 Turbo drive SDX-450V series Ver.1.0
6-19
Table 6-17: Error Event format
Byte Offset
Meaning
0 – 4
5
6 – 9
Result Message (see Diagnostic Clause)
Unused
Time-stamp (number of 1 minute increments since power-on)
When the log page becomes full, no more entries will be added until the log is cleared (using one of the methods
described previously) or a reset occurs. The current cumulative values will be returned regardless of the page
control field in the LOG SENSE CDB.
6.6.6. Tape Log Page (Sony Unique)
This page is a Sony unique page which provides information on the tape currently being used. This log cannot be
cleared and has the following format:
Table 6-20: Tape Log Page
Bit
Byte
7 6 5 4 3 2 1 0
0
Reserved
Page Code (30h)
1
Reserved
2
(MSB)
Page Length (58h)
3
(LSB)
4
(MSB) Parameter
Code
5
6
DU(0) DS(1) TSD(0) ETC(0)
TMC
(00) Reserved
LP(0)
7
Parameter Length (m)
8
Parameter
Value
3+m
This page is used to return Tape Log information to the host in a format which conforms to the LOG SENSE
command page format.
Supported Parameter Codes in this page are listed below along with their meanings:
Summary of Contents for FC TapeWare AIT-450i