FR500D Series Special Purpose Inverter for Elevator
- 29 -
Group H00: Elevator Special Purpose Group
H00.00
Special Purpose
Inverter Function
Enable
0: Invalid
1
×
1: Valid
H00.01
Brake Open Delay
0.00
~
10.00s
0.00s
×
H00.02
Start Frequency
0.00
~
10.00Hz
5.00Hz
×
H00.03
Start Frequency Holding
Time
0.00
~
10.00s
0.00s
×
H00.04
Brake Release Delay
0.00
~
10.00s
0.30s
×
H00.05
Brake Open Frequency
(Rising)
0.00
~
10.00Hz
1.00Hz
×
H00.06
Brake Release
Frequency (Rising)
0.00
~
10.00Hz
0.20Hz
×
H00.07
Brake Open Frequency
(Falling)
0.00
~
10.00Hz
1.00Hz
×
H00.08
Brake Release
Frequency (Falling)
0.00
~
10.00Hz
0.20Hz
×
H00.09
Brake Open Current
0.0
~
100.0%
40.0%
△
H00.10
Brake Open Frequency
Holding Time
0.00
~
10.00s
0.30s
×
H00.11
Brake Open Type
0: Open according to frequency
0
×
1: Open according to frequency &
current
H00.12
Emergency Operation
Frequency
0.00
~
50.00Hz
5.00Hz
△
H00.13
Maintenance Operation
Frequency
0.00
~
50.00Hz
8.00Hz
△
H00.14
Emergency Signal
Processing
0: Lift Stop
1
×
1: Lift Powered on By UPS And
Run
H00.15
Running Contactor
Release Delay
0.00~10.00s
0.20s
×
H00.16
Running Contactor
Open Delay
0.00~10.00s
0.10s
×
H00.17
Stop DC Injection Time ,
0.00~10.00s
0.50s
×
H00.18
Short Floor Function
0:Invalid
1:Short Floor Function
2:Senior Short Floor Function
0
×
H00.19
Short Floor Speed
0.0
~
100.0%
60.0%
×
H00.20
Leveling Jerk
0.0~100.0%
0.0%
×
H00.21
Leveling Jerk
Frequency
0.00~1.00
0.20
×
H00.22
Motor Mode Slip
0.00~3.00Hz
0.00Hz
×
H00.23
Generator Mode Slip
0.00~3.00Hz
0.00Hz
×
H00.24
Emergency Signal Valid
Time
0.0
~
500.0s
10.0s
×
H00.25
Emergency Signal
Invalid Time
0.0
~
1000.0s
180.0s
×
H00.26
Light load direction
0: Invalid
1
×