FR500D Series Special Purpose Inverter for Elevator
- 23 -
2: Fault reported but continue to
run
3: Fault protection disabled
Ten's digit :Power input phase
Loss (Err09)
Hundred's digit :Power output
phase loss(Err10)
Thousand's digit:Motor overload
(Err11)
Ten thousand's digit:Inverter
overload(Err12)
F11.11
Protection action 2
Unit's place
:
External equipment
fault
(
Err13)
0: Fault reported and coast to
stop
1: Fault reported to the stop
mode
2: Fault reported but continue to
run
3: Fault protection disabled
00000
×
Ten's digit: EEPROM read/write
fault (Err15)
Hundred's digit: Communication
overtime error (Err18)
Thousand's digit: PID feedback
loss (Err19)
Ten thousand's digit: Continuous
running time reached (Err20)
F11.12
Protection action 3
Unit's place: Module temperature
detection disconnection
(
Err24)
0
:
Fault reported and coast to
stop
1: Fault reported to the stop
mode
2
:
Fault reported but continue to
run
3: Fault protection disabled
30
×
Ten's digit: Load becoming 0
(Err25)
F11.14
Frequency selection for
continuing to run upon
fault
0: Current running frequency
1
×
1: Set frequency
2: Frequency upper limit
3: Frequency lower limit
4: Backup frequency upon
abnormality
F11.15
Backup frequency upon
abnormality
0.00
~
Fmax
0.00Hz
×
F11.18
Overload alarm
Unit's place: detection option:
10
×
0: Always detect