FR500D Series Special Purpose Inverter for Elevator
- 18 -
F03.15
End segment time of
acceleration of S curve
0.00
~
600.00s
1.00s
×
F03.16
Initial segment time of
deceleration of S curve
0.00
~
600.00s
1.00s
×
F03.17
End segment time of
deceleration of S curve
0.00
~
600.00s
0.00s
×
Group F04: Digital Input Terminals
F04.00
Function of terminal DI1
0: No function
1: Running forward (FWD)
2: Running reverse (REV)
3: Three-wire control
4: JOG forward
5: JOG reverse
6: Coast to stop
7: Fault reset (RESET)
8: Running suspended
9: External fault input
10: Terminal UP
11: Terminal DOWN
12: UP/DOWN (including
∧
/
∨
key) adjustment clear
13: Multi-step frequency terminal 1
14: Multi-step frequency terminal 2
15: Multi-step frequency terminal 3
16: Multi-step frequency terminal 4
17: Accel/Decel time determinant 1
18: Accel/Decel time determinant 1
19: Accel/Decel disabled(ramp
stop not inclusive)
20: Switch to auxiliary speed
setting
21: PLC status reset
22: Simple PLC paused
23: Simple PLC paused
24: PID adjustment direction
25: PID integration paused
26: PID parameter switch
27: Swing frequency pause(output
the current frequency)
28: Swing frequency reset(output
the central frequency)
29: Run command switched to
keypad control
30: Run command switched to
terminal control
31: Run command switched to
communication control
32: Count input
33: Count clear
34: Length count
35: Length clear
1
×
F04.01
Function of terminal DI2
2
×
F04.02
Function of terminal DI3
13
×
F04.03
Function of terminal DI4
14
×
F04.04
Function of terminal DI5
51
×
F04.05
Function of terminal DI6
52
×
F04.06
Function of terminal DI7
53
×